SETTINGS MENU

Feedback signal type

This setting defines the type of feedback signal emitted by the device. Possible confi

-

gurations:

OPN/REC - a feedback signal is sent immediately after the passage is unlocked

CLS/END - a feedback signal is sent after the passage is locked

PAS - a feedback signal is sent after a correct passage detection in a given direction

STR - a feedback signal is sent after initiating the rotor’s movement

Feedback signal duration

Values to choose from: 0,5 – 1,5 s.

Default setting: 0.8s

Position zero

Selecting  the  Zero  config  option  triggers  the  position  zero  configuration  mode.  This 

mode, along with the calibration mode is described in the sections below.

Calibration

Calibration submenu allows to set the engine movement necessary

parameters.

They are described in the following points.

This option is not available in gates of the following series: GA, BASIC

License

This menu allows  you to insert the license key to unlock the license. Submitting an in

-

correct key results in a temporary blockade of this menu item.

Pictograms configuration

Pictograms configuration submenu allows to configure information

pictograms. It is described in the following points.

Saving of the configuration

Save & Exit – saves the changed settings and returns to the main menu

Cancel – discards the changed settings and returns to the main menu

PICTOGRAMS CONFIGURATION

When you enter the pictograms configuration menu, you can choose two options::

• 

Standard - standard pictograms

• 

RGB - gives a possibility to choose from amongst 16 pictogram option signaling an

open passage (for the left and right side separately) and from amongst 4 pictogram 

options signaling a closed passage (for the left and right side)

LICENSE MENU

After choosing the License menu, the license number is shown on the screen. Use the 

encoder to enter a pin number. Rotate the encoder to change the number, and press to 

move the cursor to the next position. After entering the last digit, press the encoder to be 

able to navigate through the menu again.

Содержание BA3 Series

Страница 1: ...1 SG BA3 BR2 GA SERIES DEVICES CONTROL MODULE User s Manual...

Страница 2: ...2 Complete documentation GENERAL INFORMATION PEDESTRIAN TRAFFIC CONTROL DEVICE CONTROL MODULE MONTAGE MAINTENANCE AND SERVICE TECHNICAL DRAWINGS EN...

Страница 3: ...3...

Страница 4: ...PICTOGRAMS CONFIGURATION 7 LICENSE MENU 7 TEST MODE 8 SG SERIES DEVICES 8 DESCRIPTION OF THE CONTROL MODULE TERMINALS 8 SETTINGS MENU 9 ZERO POSITION CONFIGURATION 9 CALIBRATION 10 FIRST RUN 10 BA3 BR...

Страница 5: ...g software without the device manufacturer s consent The manufacturer reserves the right to introduce changes or updates to the software All devices are supplied with a stored standard software descri...

Страница 6: ...of the rotor encoder Vel current velocity of the rotor Back return to the main menu SETTINGS MENU Language configuration Choose the interface language Default setting PL Free entrance function Set the...

Страница 7: ...enu allows you to insert the license key to unlock the license Submitting an in correct key results in a temporary blockade of this menu item Pictograms configuration Pictograms configuration submenu...

Страница 8: ...ck option In devices of the BA3 BR2 and GA series the mode is used only in devices equipped in the rotor s movement support system Caution While starting the test mode no person can be found within th...

Страница 9: ...for a trigger signal If this setting is different than the central one it is recommended to use this setting in combination with the free passage in that direction Default setting cen Fire alarm conf...

Страница 10: ...e when manually moving the arm 3 Check the connection of optical sensors menu parameters A 0 digit means that the barrier is interrupted while 1 means that the barrier is not interrupted 4 The zero po...

Страница 11: ...ETTINGS MENU Coils type There are two options for each coil NOR normal coil during power failure the rotor stays blocked REV reverse coil during power failure the rotor stays unblocked Default setting...

Страница 12: ...he device s motor to identify it s parameters Notice During the calibration nothing shall interrupt the rotor s movement Otherwise the procedure has to be repeated This option is not available in GA a...

Отзывы: