Operation
LEDs
84
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | [email protected] | www.turck.com
8
Operation
8.1
LEDs
The device has the following LED indicators:
n
Power supply
n
Group and bus errors
n
Status
n
Diagnostics
PWR LED
Meaning
Off
No power supply
Green
Power supply error-free
Yellow
Undervoltage within tolerance range
Red
Undervoltage outside of tolerance range
RFON LED
Meaning
Off
Wireless field deactivated
Green
Wireless field activated
DATA LED
Meaning
Off
No tag in the field, no data transfer
Yellow flashing
Tag in the field, data transfer via the air interface
DIAG LED
Meaning
Off
No error
Red
Error
The following multicolor LEDs are freely programmable. The tables below describe the default
display functions.
DXP LEDs (digital channels, LEDs DXP0...3)
LED green
LED red
Meaning
Off
Off
No I/O signal present
Lit
Off
I/O signal present
Off
Lit
Overload at output
Flashing
Flashing
Overload of the auxiliary voltage
APPL LED
Meaning
Flashing white
Wink command active
Содержание 100000897
Страница 1: ...Your Global Automation Partner Instructions for Use TN UHF LNX UHF Reader...
Страница 2: ...2 Hans Turck GmbH Co KG T 49 208 4952 0 F 49 208 4952 264 more turck com www turck com...
Страница 19: ...V02 00 2021 05 19 Right click the Ethernet adapter Start the Topology scan Fig 16 Starting the Topology scan...
Страница 69: ...V02 00 2021 05 69 fclose fh else printf failed on writing n return 1...
Страница 75: ...V02 00 2021 05 75 else printf failed on writing n return 1 return EXIT_SUCCESS...
Страница 91: ...V02 00 2021 05 91 Restart the device to complete the update Click Reboot Fig 65 Restarting the device...
Страница 93: ...V02 00 2021 05 93 Select RS485 RFID and confirm with OK Fig 67 Selecting the RS485 interface...
Страница 97: ...V02 00 2021 05 97 Click the Select BL File button Fig 73 Button selecting a BL file...
Страница 106: ...Over 30 subsidiaries and over 60 representations worldwide www turck com 100003067 2021 05 100003067...