Commissioning
Parameterizing readers with the DTM
22
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | [email protected] | www.turck.com
7.1.3
DTM main menu – overview
The main menu provides the following functions:
Icon
Function
Description
Switch display
Shows the information bar for the connected device and DTM
version at the top of the screen.
Help about DTM
Starts the DTM help.
Help about device
Opens the data sheet of the connected reader.
Activating and deactivating Expert
mode
Opens the drop-down menu to select the access level. The
following access levels are available:
n
Basic (default setting)
n
Advanced
n
Administrator (password-protected)
Channel-wise display
Toggles the view between standard display and channel-wise
display.
Load data from database
Loads previously stored parameters from the database (e.g.
an existing project).
Store data in database
Transfers the current reader parameters to the database of
the current project.
Read data from device
Reads the set parameters from the device.
Transmit data to device
Transfers the set parameters to the device.
Compare displayed values with
database
Compares the values displayed in the DTM with the values
saved in the database.
CSV export current values
Exports the current values from the DTM to a CSV file.
The following setup windows can be opened in tabs via the main menu:
n
Basic setup
n
Antenna
n
Antenna configuration
n
Communication
n
EPC Class1 Gen2
n
Post read filter
n
Signaling
Содержание 100000897
Страница 1: ...Your Global Automation Partner Instructions for Use TN UHF LNX UHF Reader...
Страница 2: ...2 Hans Turck GmbH Co KG T 49 208 4952 0 F 49 208 4952 264 more turck com www turck com...
Страница 19: ...V02 00 2021 05 19 Right click the Ethernet adapter Start the Topology scan Fig 16 Starting the Topology scan...
Страница 69: ...V02 00 2021 05 69 fclose fh else printf failed on writing n return 1...
Страница 75: ...V02 00 2021 05 75 else printf failed on writing n return 1 return EXIT_SUCCESS...
Страница 91: ...V02 00 2021 05 91 Restart the device to complete the update Click Reboot Fig 65 Restarting the device...
Страница 93: ...V02 00 2021 05 93 Select RS485 RFID and confirm with OK Fig 67 Selecting the RS485 interface...
Страница 97: ...V02 00 2021 05 97 Click the Select BL File button Fig 73 Button selecting a BL file...
Страница 106: ...Over 30 subsidiaries and over 60 representations worldwide www turck com 100003067 2021 05 100003067...