V02.00 | 2021/05
17
7
Commissioning
The Linux operating system enables the device functions to be programmed with C, C++,
NodeJS or Python.
Additional software tools (e.g. PuTTY) are required to access the device via the console. A file
exchange between the device and a PC can be used, e.g. via WinSCP. The following login data
is stored on the device by default:
User: user
Password: password
NOTE
The reader log is not implemented by default. The protocol must be implemented
by the user.
7.1
Parameterizing readers with the DTM
The UHF settings of the device can be assigned additional parameters via the DTM.
All the required Turck software components can be downloaded via the Turck Software
Manager. The Turck Software Manager is available free of charge from
NOTE
The parameterization function up to firmware version V2.0.39.3937 is only available
in English. All parameters are written in the DTM.
The individual readers are available in different variants. When a connection is made to a con-
nected reader, the DTM automatically detects the relevant device and deactivates menu items
that are not supported. The connection cannot be established if a different variant than set in
the project tree is connected.
NOTE
Adjustable parameters are indicated in the DTM with green arrows. Fixed paramet-
ers are indicated with gray arrows.
Fig. 14: DTM – example of adjustable and fixed parameters
Requirements for extended parameter setting
n
PACTware must be installed.
n
The DTM for UHF readers must be installed.
n
The device must be connected to a PC via the serial interface.
Содержание 100000897
Страница 1: ...Your Global Automation Partner Instructions for Use TN UHF LNX UHF Reader...
Страница 2: ...2 Hans Turck GmbH Co KG T 49 208 4952 0 F 49 208 4952 264 more turck com www turck com...
Страница 19: ...V02 00 2021 05 19 Right click the Ethernet adapter Start the Topology scan Fig 16 Starting the Topology scan...
Страница 69: ...V02 00 2021 05 69 fclose fh else printf failed on writing n return 1...
Страница 75: ...V02 00 2021 05 75 else printf failed on writing n return 1 return EXIT_SUCCESS...
Страница 91: ...V02 00 2021 05 91 Restart the device to complete the update Click Reboot Fig 65 Restarting the device...
Страница 93: ...V02 00 2021 05 93 Select RS485 RFID and confirm with OK Fig 67 Selecting the RS485 interface...
Страница 97: ...V02 00 2021 05 97 Click the Select BL File button Fig 73 Button selecting a BL file...
Страница 106: ...Over 30 subsidiaries and over 60 representations worldwide www turck com 100003067 2021 05 100003067...