48
Lifeline 4000 Advanced User Guide (B)
Copyright © 2000 Tunstall Group Ltd.
Example
Set the action for Temperature A monitors so that a light is flashed
1.
Enter local programming mode by holding down the
key and then holding down the
# key until the unit beeps. Release the # key first, and then the
key.
2.
Enter the parameter—press
1 5 0
.
3.
Delete the old value using the C key (display version only).
4.
Enter 6 0 0 0 0 2 9 9 , and then press
.
5.
End local programming by pressing the
Cancel
key.
Imagine we are setting up a Lifeline 4000 in a house. The three residents in the house need
support during the day, and all are potentially vulnerable to the cold. Consequently, we want to
monitor the temperature. We have fixed several temperature sensors around the home, and each
one will trigger if the temperature drops below 18ºC. When the temperature drops below this
level we want a call to be raised. However, we also want a light to be flashed so that any carer in
the home is made aware of the problem so they can check the central heating.
The first two numbers are set to 60 to provide a 60 seconds prealarm delay. If there are any
carers present they will be able to cancel the alarm call and deal with the problem themselves. The
next figure is zero because we want all of the call progress indicators. However, we do not want
this alarm type to answer a call, reset the inactivity timer or raise an intruder call. Consequently,
we set the fourth digit to zero. The fifth digit is zero because we want this type of call to use call
sequence 10. The external output is set to 2, so that this type of alarm will always turn the
external output on. The next two figures are both 9 because the output will be flashed on for 1.8
seconds and then flashed off for 1.8 seconds. The output has been connected to a relay, in
accordance with the instructions in chapter 4 of this guide.
Содержание Lifeline 4000
Страница 4: ...4 Lifeline 4000 Advanced User Guide B Copyright 2000 Tunstall Group Ltd...
Страница 24: ...24 Lifeline 4000 Advanced User Guide B Copyright 2000 Tunstall Group Ltd...
Страница 72: ...72 Lifeline 4000 Advanced User Guide B Copyright 2000 Tunstall Group Ltd...
Страница 74: ...74 Lifeline 4000 Advanced User Guide B Copyright 2000 Tunstall Group Ltd...
Страница 79: ...Copyright 2000 Tunstall Group Ltd Lifeline 4000 Advanced User Guide B 79...