Draco 3000 / Draco 4000
27
Progression
,
button 1, picture 45
The value of progression shows how many centimetres the machine goes forward when the
supporting wheel rotates one turn. Experience tells us that with a 420/55-17 tyre the reading is 276
cm. However, cultivating the field and types of soil may affect progression by several percents. If you
need to change the reading, you press button 1 to activate the change menu. You can increase the
reading with
+
button and reduce it with
-
button. Increasing the reading gives more hectares and
reducing the reading gives less hectares. The value is accepted by pressing
OK
button. The change
menu disappears at the same time.
Working width
,
button 2, picture 45
There is no need to change the working width, but it can be done using the same principle as the
progression.
Screen brightness
,
button 3, picture 45
Brightness can be adjusted to 15 different degrees. Press button 3 to activate the change menu.
When you press button
+
, brightness increases. When you press button
-
, brightness decreases.
When screen brightness is good, accept it by pressing
OK
button. The change menu disappears at
the same time.
Alarm sound
,
button 4, picture 45
Alarm sound can be switched either on or off. This happens when you press button 4. If the button
shows X as well as a loudspeaker image, the alarm sound is switched off. If you press the button
once, the X disappears and alarm sound is switched on.
Axle & Container monitoring
,
buttons 5, 6, 7 and 8, picture 45
Button 5: Monitoring the rotation of fertilizer axle
Button 6: Monitoring the rotation of seed axle
Button 7: Monitoring the levels in the fertilizer container
Button 8: Monitoring the levels in the seed container
When you press any of the above mentioned buttons, a change menu for the function in question is
activated.
With a higher reading value the time delay of the alarm is longer than with a lower reading value.
Changes are made in the change menu with buttons
+
and
-
. The value is accepted with the button
OK
, and the change menu disappears.
Note!
If axle monitoring or container monitoring are set to the value 0 the monitoring is switched off.
This might be necessary in the following cases, for example:
-Extremely small amounts of seed are sown and the feed axle rotates so slowly that even value 1
raises alarm
-Seed container has a very small amount of small seeds and the container monitoring raises the
alarm for nothing
-Only seeds are sown so monitoring the empty fertilizer container needs to be switched off