Solenoid data
Voltage
12 V
24 V
Minimum supply voltage
9.5 V
DC
19 V
DC
Maximum supply voltage (continuous)
14.6 V
DC
29 V
DC
Maximum current
1050 mA
500 mA
Nominal coil resistance @ 20 °C [70 °F]
8.4 Ω
34.5 Ω
PWM Range
70-200 Hz
PWM Frequency (preferred)
*
100 Hz
IP Rating (IEC 60 529) + DIN 40 050, part 9
IP 67 / IP 69K (part 9 with mating connector)
Bi-directional diode cut off voltage
28 V
DC
53 V
DC
*
PWM signal required for optimum control performance.
Pump output flow direction vs. control signal
Shaft rotation
CW
CCW
Coil energized
*
C1
C2
C1
C2
Port A
in
out
out
in
Port B
out
in
in
out
Servo port pressurized
M5
M4
M5
M4
*
For coil location see Installation Drawings.
Control Response
MP1 controls are available with optional control passage orifices to assist in matching the rate of
swashplate response to the application requirements. The time required for the pump output flow to
change from zero to full flow (acceleration) or full flow to zero (deceleration) is a net function of spool
porting, orifices, and charge pressure. A swashplate response table is available for each frame indicating
available swashplate response times. Testing should be conducted to verify the proper orifice selection
for the desired response.
Typical response times shown below at the following conditions:
Δp
250 bar [3626 psi]
Viscosity and temperature
30 mm²/s [141 SUS] and 50 °C [122 °F]
Charge pressure
20 bar [290 psi]
Speed
1800 min
-1
(rpm)
Response time, FNR
Stroking
direction
0.8 mm [0.03 in]
orifice
1.0 mm [0.04 in]
orifice
1.3 mm [0.05 in]
orifice
No orifice
28/32
38/45
28/32
38/45
28/32
38/45
28/32
38/45
Neutral to
full flow
2.1 s
2.6 s
1.1 s
1.6 s
0.8 s
1.1 s
0.7 s
0.7 s
Full flow to
neutral
1.1 s
1.8 s
0.9 s
1.0 s
0.6 s
0.7 s
0.3 s
0.3 s
Service Manual
MP1
Operation
©
Danfoss | July 2017
AX00000244en-US0103 | 25
Содержание DP20-4H
Страница 11: ......
Страница 12: ......
Страница 26: ......
Страница 27: ......
Страница 28: ......
Страница 29: ......
Страница 30: ......
Страница 31: ......
Страница 32: ......
Страница 33: ......
Страница 34: ......
Страница 35: ...Service Manual Variable Displacement Pumps MP1 powersolutions danfoss com ...
Страница 93: ...Service Manual MP1 Danfoss July 2017 AX00000244en US0103 59 ...
Страница 94: ...Service Manual MP1 60 Danfoss July 2017 AX00000244en US0103 ...
Страница 95: ...Service Manual MP1 Danfoss July 2017 AX00000244en US0103 61 ...
Страница 110: ......
Страница 111: ......
Страница 112: ......
Страница 113: ......
Страница 115: ......
Страница 154: ......
Страница 156: ...www dexteraxle com OPERATION MAINTENANCE SERVICE MANUAL 600 8 000 lb Axles Related Components ...
Страница 238: ...Service Record Date Service Performed Mileage ...
Страница 239: ...Service Record Date Service Performed Mileage ...
Страница 240: ...Service Record Date Service Performed Mileage ...