3

 
 

1a. Windows 

The window must operate correctly and smoothly. Lubrication or cleaning of 
hardware may be required.  This motor system will not operate correctly if the window/skylights 
manual hardware is not functioning properly. 
Note the direction of rotation for crank to open the window as either Clockwise or Counter 
Clockwise (when facing the window operator) 
 
 
 
 
 

Circle the direction to OPEN:

   

COUNTER-CLOCKWISE

 

 

CLOCKWISE

 

 
 
 
 
 
 
 

1b. Skylights

 

The skylight lid must weight less than 80 lbs. (40 lbs. at the chain).   
A hand crank should be used to verify the skylight operates smoothly.   
Lubrication, cleaning or re-alignment of hardware may be required.  
 

 

 

Must weigh less 
than 40lb (18 kg) 

Содержание Sentry II WLS

Страница 1: ...o This equipment does not provide a method to shut off power and should be connected to a dedicated breaker or fused power circuit capable of providing 50 watts of power per control o The Sentry 2 sy...

Страница 2: ...atts and multiply by the number of windows skylights to be backed up by a given UPS Below is a list of the manufacturers who produce uninterruptable power supplies which we have approved as compatible...

Страница 3: ...the direction of rotation for crank to open the window as either Clockwise or Counter Clockwise when facing the window operator Circle the direction to OPEN COUNTER CLOCKWISE CLOCKWISE 1b Skylights Th...

Страница 4: ...e adapter B as shown Secure motor with bracket C A number of mounting positions are provided by the bracket use the one which provides the best alignment with the window frame Be sure to use both the...

Страница 5: ...shown Secure motor with bracket C using the appropriate screw Be sure to use both the isolation grommet D and the push on fastener E 4 Align Tighten Collar Align motor to window or skylight and tight...

Страница 6: ...the floor It is intended to prevent personal injury and or window damage during operation On vents above 8 ft a jumper wire included is installed into the Grey terminals of block 10 6 Secure Wires In...

Страница 7: ...ended application 8 Route and Install wires Route low voltage wires from motor location including any accessory wires such as rain sensor power blind etc into control switch opening Route appropriate...

Страница 8: ...tion required When the box is installed after the wall is finished enclosed the mounting wings should be broken off and discarded The wall clamps engage the wall automatically as the screws are tighte...

Страница 9: ...n wire diagram need to be configured for each motor application 1 2 3 4 5 6 on off 1 Must stay set to on 2 Motor Application Window off Skylight on 3 Drive motor direction to open from Step 1a CW off...

Страница 10: ...2 3 4 5 6 on off 1 Must stay set to on 2 Motor Application Window application off Skylight application on 3 Drive motor direction to Open CW off Or CCW on 4 Motorized Blind No Blind present off Blind...

Страница 11: ...ored Note Upon power up the unit should Close the window skylight If the window skylight Opens Refer to the window crank direction in Step 1a and Dip Switch Settings Step 11 Disconnect power change di...

Страница 12: ...side of wall box If functions are reversed blind buttons controlling window etc the ribbon plug needs to be reversed 16 Establishing Operating Memory Upon pressing the open button the unit will cycle...

Страница 13: ...sition is approx 75 of full opening range Pressing Close on either the wall switch or the remote will Close the window skylight Pressing the opposite function while the motor is running such as pressi...

Страница 14: ...ssing an open or close button on the remote This indicates that the control did not receive a complete command You may need to move closer with the remote and or repeat the command Check battery statu...

Страница 15: ...Sensor Guidelines Install the sensor with grid exposed Do Not use rain sensor if the control is being used as a Smoke Vent See HPI Wire with 22 AWG 2 conductor shielded twisted pair 50 ft 15m Max Note...

Страница 16: ...will function normally c If window skylight is opening in motion when momentary close is given the motor will stop In this way a partial opening position is achieved 2 System Status Blue White termina...

Страница 17: ...smoke detection ventilation function via the HPI the blinds will open automatically before the skylight is opened The following companys can provide information on Blinds or Shades that are compatibl...

Страница 18: ...ation can be performed to re learn the skylights full range of motion This is called a forced Reset A forced Reset can be initiated by the following methods 1 By changing any of the Dip Switches See S...

Страница 19: ...Warning Changes or modifications not expressly approved by Truth Hardware could void the FCC compliance and negate your authority to operate the product FCC Declaration of Conformity According to 47...

Страница 20: ...An FKI Industries Company 700 West Bridge Street Owatonna MN 55060 1 800 324 4487 www truth com...

Отзывы: