Regulatory

 

Compliance

 

 

United States of America 

Federal Communications Commission (FCC)

 

Unintentional emitter per FCC Part 15 

 

Note:  This equipment has been tested and found to comply with the limits for a Class B digital device, 
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against 
harmful interference in a residential installation. This equipment generates, uses, and can radiate radio 
frequency energy and, if not installed and used in accordance with the instructions may cause harmful 
interference to radio communications.  However, there is no guarantee that interference will not occur in a 
particular installation.  If this equipment does cause harmful interference to radio or television reception, 
which can be determined by turning the equipment off and on, the user is encouraged to try to correct the 
interference by one or more of the following measures: 

 

o

 

Reorient or relocate the receiving antenna. 

o

 

Increase the separation between the equipment and receiver. 

o

 

Connect the equipment into an outlet on a circuit different from that to 
which the receiver is connected. 

o

 

Consult the dealer or an experienced radio/TV technician for help. 

 

Warning

: Changes or modifications not expressly approved by Truth Hardware could void the FCC 

compliance and negate your authority to operate the product.

 

 

FCC Declaration of Conformity 

According to 47 CFR, Parts 15.107 and 15.109 Class B 

 

Responsible party:

   Truth Hardware, 700 West Bridge St., Owatonna, MN  55060  

 

 

 

www.truth.com  or 1-800-324-4487 

 

Product:

 Sentry 2 Hand Held Remote (43.53) 

 

This device complies with part 15 of the FCC Rules.  Operation is subject to the following two conditions: (1) 
This device may not cause harmful interference, and (2) this device must accept any interference received 
including interferences that may cause undesired operation.

 

 

Canada 

Industry Canada (IC) 

Unintentional emitter per ICES-003 

 

This class B digital apparatus complies with Canadian ICES-003. 
Cet appareil numérique de la classe B est conforme á la norme NMB-003 du Canada. 
 
Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this 
device must accept any interference, including interference that may cause undesired operation of the 
device.

 

 

Europe 

European Community EMC Directive (CE)

 

Compliance with these directives implies conformity to the following 
European Norms or Regulations: 

 

Emissions

   

 

 

 

 

Immunity

 

ETSI  EN 300-220-1 v1.3.1 (2000-09)    

 

ETSI  EN 301 489-3 v1.2.1 (2000-08) 

ETSI  EN 300-220-3 v1.1.1 (2000-09) 

 

 

EN  55014-2: 1997 

ETSI  EN 301 489-3 v1.2.1 (2000-08) 
EN  55014-1: 1997 

Содержание Sentry II WLS

Страница 1: ...o This equipment does not provide a method to shut off power and should be connected to a dedicated breaker or fused power circuit capable of providing 50 watts of power per control o The Sentry 2 sy...

Страница 2: ...atts and multiply by the number of windows skylights to be backed up by a given UPS Below is a list of the manufacturers who produce uninterruptable power supplies which we have approved as compatible...

Страница 3: ...the direction of rotation for crank to open the window as either Clockwise or Counter Clockwise when facing the window operator Circle the direction to OPEN COUNTER CLOCKWISE CLOCKWISE 1b Skylights Th...

Страница 4: ...e adapter B as shown Secure motor with bracket C A number of mounting positions are provided by the bracket use the one which provides the best alignment with the window frame Be sure to use both the...

Страница 5: ...shown Secure motor with bracket C using the appropriate screw Be sure to use both the isolation grommet D and the push on fastener E 4 Align Tighten Collar Align motor to window or skylight and tight...

Страница 6: ...the floor It is intended to prevent personal injury and or window damage during operation On vents above 8 ft a jumper wire included is installed into the Grey terminals of block 10 6 Secure Wires In...

Страница 7: ...ended application 8 Route and Install wires Route low voltage wires from motor location including any accessory wires such as rain sensor power blind etc into control switch opening Route appropriate...

Страница 8: ...tion required When the box is installed after the wall is finished enclosed the mounting wings should be broken off and discarded The wall clamps engage the wall automatically as the screws are tighte...

Страница 9: ...n wire diagram need to be configured for each motor application 1 2 3 4 5 6 on off 1 Must stay set to on 2 Motor Application Window off Skylight on 3 Drive motor direction to open from Step 1a CW off...

Страница 10: ...2 3 4 5 6 on off 1 Must stay set to on 2 Motor Application Window application off Skylight application on 3 Drive motor direction to Open CW off Or CCW on 4 Motorized Blind No Blind present off Blind...

Страница 11: ...ored Note Upon power up the unit should Close the window skylight If the window skylight Opens Refer to the window crank direction in Step 1a and Dip Switch Settings Step 11 Disconnect power change di...

Страница 12: ...side of wall box If functions are reversed blind buttons controlling window etc the ribbon plug needs to be reversed 16 Establishing Operating Memory Upon pressing the open button the unit will cycle...

Страница 13: ...sition is approx 75 of full opening range Pressing Close on either the wall switch or the remote will Close the window skylight Pressing the opposite function while the motor is running such as pressi...

Страница 14: ...ssing an open or close button on the remote This indicates that the control did not receive a complete command You may need to move closer with the remote and or repeat the command Check battery statu...

Страница 15: ...Sensor Guidelines Install the sensor with grid exposed Do Not use rain sensor if the control is being used as a Smoke Vent See HPI Wire with 22 AWG 2 conductor shielded twisted pair 50 ft 15m Max Note...

Страница 16: ...will function normally c If window skylight is opening in motion when momentary close is given the motor will stop In this way a partial opening position is achieved 2 System Status Blue White termina...

Страница 17: ...smoke detection ventilation function via the HPI the blinds will open automatically before the skylight is opened The following companys can provide information on Blinds or Shades that are compatibl...

Страница 18: ...ation can be performed to re learn the skylights full range of motion This is called a forced Reset A forced Reset can be initiated by the following methods 1 By changing any of the Dip Switches See S...

Страница 19: ...Warning Changes or modifications not expressly approved by Truth Hardware could void the FCC compliance and negate your authority to operate the product FCC Declaration of Conformity According to 47...

Страница 20: ...An FKI Industries Company 700 West Bridge Street Owatonna MN 55060 1 800 324 4487 www truth com...

Отзывы: