17. Normal Operation

 

 
The normal operating functions are as follows: 

  Pressing “Open” on either the wall switch or the remote will “Open” the 

window/skylight, If locks are present they will function as part of the window.  

  Note that the full open position of a window varies with operating hardware 

and sash width.  The typical stop position is approx. 75% of full opening range. 

  Pressing “Close” on either the wall switch or the remote will “Close” the 

window/skylight 

  Pressing the “opposite” function while the motor is running (such as pressing 

“Close” while the window/skylight is opening) will “Stop” the motor.  The motor is 
restarted by pressing either “Open” or “Close” again. 

  During motor operation the LED in the center of the wall plate should glow 

“Green”. This indicates normal operation.

 

 
                                        

 

 

 
 
 
 

 

Status 

Light 

Open 

Window 

Or 

Skylight 

Close 

Window 

Or 

Skylight 

Open

Blind

Close 

Blind 

Содержание Sentry II WLS

Страница 1: ...o This equipment does not provide a method to shut off power and should be connected to a dedicated breaker or fused power circuit capable of providing 50 watts of power per control o The Sentry 2 sy...

Страница 2: ...atts and multiply by the number of windows skylights to be backed up by a given UPS Below is a list of the manufacturers who produce uninterruptable power supplies which we have approved as compatible...

Страница 3: ...the direction of rotation for crank to open the window as either Clockwise or Counter Clockwise when facing the window operator Circle the direction to OPEN COUNTER CLOCKWISE CLOCKWISE 1b Skylights Th...

Страница 4: ...e adapter B as shown Secure motor with bracket C A number of mounting positions are provided by the bracket use the one which provides the best alignment with the window frame Be sure to use both the...

Страница 5: ...shown Secure motor with bracket C using the appropriate screw Be sure to use both the isolation grommet D and the push on fastener E 4 Align Tighten Collar Align motor to window or skylight and tight...

Страница 6: ...the floor It is intended to prevent personal injury and or window damage during operation On vents above 8 ft a jumper wire included is installed into the Grey terminals of block 10 6 Secure Wires In...

Страница 7: ...ended application 8 Route and Install wires Route low voltage wires from motor location including any accessory wires such as rain sensor power blind etc into control switch opening Route appropriate...

Страница 8: ...tion required When the box is installed after the wall is finished enclosed the mounting wings should be broken off and discarded The wall clamps engage the wall automatically as the screws are tighte...

Страница 9: ...n wire diagram need to be configured for each motor application 1 2 3 4 5 6 on off 1 Must stay set to on 2 Motor Application Window off Skylight on 3 Drive motor direction to open from Step 1a CW off...

Страница 10: ...2 3 4 5 6 on off 1 Must stay set to on 2 Motor Application Window application off Skylight application on 3 Drive motor direction to Open CW off Or CCW on 4 Motorized Blind No Blind present off Blind...

Страница 11: ...ored Note Upon power up the unit should Close the window skylight If the window skylight Opens Refer to the window crank direction in Step 1a and Dip Switch Settings Step 11 Disconnect power change di...

Страница 12: ...side of wall box If functions are reversed blind buttons controlling window etc the ribbon plug needs to be reversed 16 Establishing Operating Memory Upon pressing the open button the unit will cycle...

Страница 13: ...sition is approx 75 of full opening range Pressing Close on either the wall switch or the remote will Close the window skylight Pressing the opposite function while the motor is running such as pressi...

Страница 14: ...ssing an open or close button on the remote This indicates that the control did not receive a complete command You may need to move closer with the remote and or repeat the command Check battery statu...

Страница 15: ...Sensor Guidelines Install the sensor with grid exposed Do Not use rain sensor if the control is being used as a Smoke Vent See HPI Wire with 22 AWG 2 conductor shielded twisted pair 50 ft 15m Max Note...

Страница 16: ...will function normally c If window skylight is opening in motion when momentary close is given the motor will stop In this way a partial opening position is achieved 2 System Status Blue White termina...

Страница 17: ...smoke detection ventilation function via the HPI the blinds will open automatically before the skylight is opened The following companys can provide information on Blinds or Shades that are compatibl...

Страница 18: ...ation can be performed to re learn the skylights full range of motion This is called a forced Reset A forced Reset can be initiated by the following methods 1 By changing any of the Dip Switches See S...

Страница 19: ...Warning Changes or modifications not expressly approved by Truth Hardware could void the FCC compliance and negate your authority to operate the product FCC Declaration of Conformity According to 47...

Страница 20: ...An FKI Industries Company 700 West Bridge Street Owatonna MN 55060 1 800 324 4487 www truth com...

Отзывы: