8.
Now set heater temperature according to the solvent being used to extract. (i.e
Ethanol=180-194F.)
Adjust Pressure On System (To compensate for heat expansion)
1.
Once the heater is up to operating temperature you need to adjust the pressure in the
heating system by removing some water. THIS IS VERY DANGEROUS, the water
coming out will be EXTREMELY HOT
2.
Get a bucket to capture water from the temperature/pressure valve or let the water
drain out if plumbed properly.
3.
Lift up on the Temperature/pressure valve on the heater manifold and set
accordingly:
Electric heater set pressure between 15-20.
Gas heater set the pressure to 45-55 PSI.
4.
The heating system is now filled, primed and ready to operate.
Contact Hubbell Support
For questions/concerns/troubleshooting regarding your water heater, please contact
Hubbell.
Keep in mind that they are located in Eastern Standard Time
Call:
(800) 647-3165
Or: (203) 378-2659