AV15 INSTALLATION MANUAL | TruSteel AutoVap15 Installation Instructions | v. 1.3
18 / 43
The AV15+ has (2) pumps that are powered by VFD's: The feed pump (located on the left)
and the Auto-Discharge Pump (located on the right).
How Auto-Discharge Works
:
The feed pump, controlled by the remote control, continuously feeds material through the
system. As the solvent collects in the Solvent Vessel (about 3-4 gallons), the bottom float
switch will trigger. This will activate the Auto-Discharge Pump and discharge the solvent.
When the solvent is completely discharged, the Auto-Discharge Pump will deactivate.
There is a second, higher float switch in the Solvent Vessel that will automatically STOP the
feed pump if triggered. This ensures you will never overfill your Solvent Vessel in the event
the bottom float mechanism ever fails.
Technical Documents and Instructions
Lenze VFD Installation Manual
·
AC Tech Lenze SMVector NEMA 4X Flyer
·
AC Tech Lenze SMVector Brochure
·
AC Tech Lenze SMVector Datasheet
·
AC Tech Lenze SMVector Wiring Tutorial
·
Lenze SMV Frequency Inverter Operating Instructions
·
AC Tech Lenze SMVector 1HP CAD Drawing
·
AC Tech Lenze Keypad Installation Instructions
·
AC Tech Lenze SMVector EMP Programmer Operating Instructions
Note: Only the Feed Pump VFD will have a remote control.
Содержание AV15
Страница 21: ...AV15 INSTALLATION MANUAL TruSteel AutoVap15 Installation Instructions v 1 3 21 43 ...
Страница 23: ...AV15 INSTALLATION MANUAL TruSteel AutoVap15 Installation Instructions v 1 3 23 43 2 RECOVERYASSEMBLY ...
Страница 26: ...AV15 INSTALLATION MANUAL TruSteel AutoVap15 Installation Instructions v 1 3 26 43 ASSEMBLY ...
Страница 42: ...AV15 INSTALLATION MANUAL TruSteel AutoVap15 Installation Instructions v 1 3 42 43 ...