background image

This product, its parts and components have a  1 year warranty against defects in its manufacture, operation and workmanship, 
except when: the product has been used in conditions other than those recommended, or has not been operated according 
to the instructions, or has been altered or repaired by personnel not authorized by

In order to make the warranty valid or to purchase components and spare  parts, you must present the product and its proof 
of purchase at Av. San Isidro #110, Col. Industrial San Antonio, ALC. Azcapotzalco, C.P. 02760, CDMX, Mex. or at the store where 
you bought it, or at a                                       service center listed in the attached warranty policy and/or at 

www.truper.com

 

Transportation costs resulting from compliance of this warranty will be covered by  
For questions or comments, call 

01-800-690-6990.

Imported by: 

Truper, S.A. de C.V. 

Made in China, Parque Industrial #1, Jilotepec, Edo. de Méx., 
Méx. C.P. 54240

Warranty policy

In the event of any problem contacting a Service Center, please see our webpage  www.truper.com to get an updated 

list, or call our toll-free numbers 

01(800) 690-6990 or 01 (800) 018-7873 

to get information about the nearest 

Truper® Authorized Service Center.

Model: 

 COMP-240LH

Code: 

 19365

This warranty applies to:

Stamp of the business:
Delivery Date:

03-2019

Содержание 19365

Страница 1: ...19365 NOTA IMPORTANTE Este producto no debe quedar expuesto a goteo o salpicaduras por l quidos Instructivo Compresor horizontal de banda Lea este Instructivo por completo antes de usar la herramienta...

Страница 2: ...na o se cruce cuando est en funcionamiento 12 No extienda su radio de acci n Evite toda postura que cause cansancio Cuide de que su posici n sea segura y de que conserve el equilibrio 13 Mantenga las...

Страница 3: ...a una operaci n segura Instale una v lvula sin retorno o de corte en la tuber a de entrega si el compresor se acoplar en paralelo con otro compresor o si se conectar a un sistema de suministro de aire...

Страница 4: ...LIDA 6 5 mm L TANQUE M MAN METRO DE TANQUE N LLANTAS O V LVULA DE PURGA P BOT N DE INTERRUPTOR Q PROTECTOR DE SOBRECARGA ACCESORIOS 1 Botella de aceite 2 Filtros de aire 1 Tap n del dep sito de aceite...

Страница 5: ...antenimiento preventivo diario ACEITE Revise el nivel del aceite del c rter y rellene de ser necesario Si su compresor no se usa diariamente revise el nivel de aceite del c rter antes de arrancarlo Ca...

Страница 6: ...a con un protector termomagn tico que evita que el motor sufra un calentamiento excesivo El motor se apaga cuando se activa el interruptor Fig L para restablecer el motor siga los siguientes pasos 1 P...

Страница 7: ...ompresor ha operado durante un periodo considerable en un lugar h medo 1 Es necesario drenar el tanque 2 Fugas de aire en la tuber a en la m quina o en el sistema externo 3 Fugas en la v lvula de segu...

Страница 8: ...eemplazar la v lvula acuda a un CSAT 1 Revise la tensi n de la l nea de alimentaci n los fusibles o corrija la sobrecarga del motor 2 Consulte a un electricista calificado 1 Cambie y use el aceite cor...

Страница 9: ...SUCURSAL GUADALAJARA AV ADOLFO B HORN 6800 COL SANTA CRUZ DEL VALLE C P 45655 TLAJOMULCO DE ZU IGA JAL TEL 01 33 3606 5285 AL 90 MICHOAC N FIX FERRETER AS AV PASEO DE LA REP BLICA 3140 A COL EX HACIEN...

Страница 10: ...s recomendadas o no se haya operado de acuerdo al instructivo o haya sido alterado o reparado por personal no autorizado por Para hacer v lida la garant a o adquirir piezas y componentes deber present...

Страница 11: ...19365 Horizontal belt drive air compressor Manual IMPORTANT NOTICE This product should not be exposed to liquids dripping or splashing Read the user s manual thoroughly before operating this tool CAU...

Страница 12: ...ing one hand and enables to use both hands Keep proper footing and balance at all times Do not overreach over or walk across the tool when is running 12 Do not extend your range of action Avoid a stan...

Страница 13: ...valve in the inlet piping in case compressor shall be parallel coupled with a second compressor or if it will be connected to an air supply system Double check all piping and hoses connected to the c...

Страница 14: ...URGE VALVE P SWITCH BUTTON Q THERMAL OVERLOAD PROTECTOR ACCESSORIES 1 Oil Bottle 2 Air Filters 1 Oil Deposit Cap 4 Wheels 4 Rondanas 4 Cotter pins BEFORE CONNECTING THE COMPRESSOR VERIFY THE FOLLOWING...

Страница 15: ...ciency for a long period of time Preventive daily maintenance OIL Check oil level in the casing and refill if necessary If the compressor is not used every day check the oil level in the casing before...

Страница 16: ...or is built with a thermal magnetic protector that prevents the motor from excessive heating The engine shuts down when the switch is activated See figure L to reset the engine follow these steps 1 Pr...

Страница 17: ...rating in a damp place for a long period of time 1 Draining the tank is necessary 2 Air leaks in pipeline in the machine or the external system 3 Leaks in the tank security valve 1 There is a possibil...

Страница 18: ...a TASC 1 Double check feeding line voltage the fuses or correct the motor overload 2 Consult with a qualified electrician 1 Change and use the right type of oil 2 Add oil to the casing up to the righ...

Страница 19: ...GUADALAJARA AV ADOLFO B HORN 6800 COL SANTA CRUZ DEL VALLE C P 45655 TLAJOMULCO DE ZU IGA JAL TEL 01 33 3606 5285 AL 90 MICHOAC N FIX FERRETER AS AV PASEO DE LA REP BLICA 3140 A COL EX HACIENDA DE LA...

Страница 20: ...0 CDMX Mex or at the store where you bought it or at a service center listed in the attached warranty policy and or at www truper com Transportation costs resulting from compliance of this warranty wi...