TECHNICAL CHARACTERISTICS:

Voltage:

 

220 V~

Frequency:

 

60 Hz

Current:

 

10 A

Speed:

 

3 450 RPM

Motor Rated Power: 

3 Hp

Maximum Motor Power:

  4 Hp

Maximum Pressure:

 

116 PSI

Tank Capacity:

 

63.4 Gal

IP Grade:

 IP20

Air Flow:

  

7,7 CFM - 40 PSI

 

 

5,7 CFM - 90 PSI

 

Power Cord Grips Type:

 Y

All conductors are:

  1,5 mm

2

 x 3C with 221 ºF Insulating 

Temperature

Build quality:

 Basic insulation.

Insulation quality:

 Class l

Thermal insulation of motor winding:

 Class B

 

                

To avoid risk of electrical shock or serious accident, 

if power cord gets damaged it shall be repaired by the manufacturer 

or by Truper

®

 Authorized Service Center 

Power cord grips used in this product: Type”Y”.

Assembly design in this product causes insulation to be affected 

by liquid spills or splashing.

                      Before gaining access to terminals, all 

power circuits shall be disconnected.

    

We do not recommend using power 

cord extensions with compressors.  Using that type of 

extension cause power drops resulting in motor potency 

loss and overheating.  Instead of using an extension cord 

increase the compressor’s action scope connecting a 

longer hose into the outlet. Connect additional hose 

lengths as needed.

BELT DRIVE AIR COMPRESSORS.

-  Do not use compressed air to clean clothes.

-  Do not apply compressed air directly to skin.

-  Do not apply compressed air for breathing purposes  

unless the air is filtered with a filter specifically for built to 

that purpose.

-  Do not use open-air piping.  It could lash out and   

cause injuries.

-  Do not use flammable liquids to clean the compressor.

-  Do not use an open fire to inspect inside the compressor or 

the pressure deposit.

-  Wear eye protection when using compressed air to clean  

the unit.

-  Use caution not to blow particles towards people: always use 

an air gun for cleaning.

-  Double-check all the auxiliary fixtures are functioning 

adequately and have the right capacity for the application.

-  Inspect regularly that all covers are fixed and firmly set.

-  Replace all parts, tools and accessories when unfit for a safe 

operation.

-  Install a check-valve or a cut valve in the inlet piping in case 

compressor shall be parallel coupled with a second 

compressor or if it will be connected to an air supply system.

-  Double-check all piping and hoses connected to the 

compressor have the right diameter, and, adequate 

resistance for the maximum pressure delivered by the 

compressor.

-  Install the compressor making available an adequate 

ventilation air supply towards the unit. Use care not to 

restrict air ducts through the inlets in the cover and  

motor fan.

INSPECT:

Inspect the pumps’ rotation direction during the initial start up.  

Verify any modification in the electric components’ or connections.

Turn off the compressor and disconnect from the power outlet.  

Ventilate completely before disassembling any component or 

making any maintenance service.

BELT DRIVE AIR COMPRESSORS

Belt drive air compressors are shipped with the wheels installed.  

The model installed on wheels absorbs vibration but shall be set 

on firm and leveled ground.

INSTALLATION AND VENTILATION

To service the compressor allow adequate access and free space 

up and around the unit. It needs adequate protection against 

weather. Good ventilation is essential. To gain maximum efficiency 

admission air shall be as cold and clean as possible (a 37.4 ºF 

drop in temperature will increase 1% the delivered air volume). 

Gas impurities and particles, abrasive dust and corrosive gasses 

are especially harmful.  The exhaust vapors are hazardous if 

compressed air is used to supply breathing devices.

Set the compressor as far away as possible from the work areas 

to prevent from suctioning particles generated by the job (paint, 

dust, etc.)

CONNECTION TO THE MAIN POWER SUPPLY

The compressor shall be set as close as possible to the main 

power supply.  Double-check the power supply matches the voltage 

indicated in the motor nameplate.

 

              

This unit must be grounded.

 

              

The power cables are coded with the following 

colors:

GREEN AND YELLOW      GROUND

BLUE                                NEUTRAL

BROWN                            CURRENT

3

COMPRESSOR FULL DIAGRAM

A) HANDLE

B)  MOTOR INTER-CONNECTION BOX

C) MOTOR

D)  CHECK VALVE

E)  BELT WITH GUARD

F)  AIR FILTER

G)  OIL FILLING CAP

H)  PUMP CASING

I)  OIL SPYHOLE

J) PRESSURESTAT

K)  1/4’’ OUTLET VALVES

L) TANK

M)  TANK MANOMETER

N) WHEELS

O)  PURGE VALVE

P)  SWITCH BUTTON

Q)  THERMAL OVERLOAD PROTECTOR

 

ACCESSORIES:

1 Oil Bottle

2 Air Filters 

1 Oil Deposit Cap

4 Wheels

4 Rondanas

4 Cotter pins

BEFORE CONNECTING THE COMPRESSOR VERIFY THE 

FOLLOWING:

Feeding voltage shall match voltage indicated in the compressor 

nameplate.

Air gauge readings shall be zero.

Oil level in the compressor pump casing shall reach the mark in 

the level indicator. 

O

A

A

N

N

L

K

M

J

P

B

C

D

E

F G

H

I

Q

C

D

Содержание 19365

Страница 1: ...19365 NOTA IMPORTANTE Este producto no debe quedar expuesto a goteo o salpicaduras por l quidos Instructivo Compresor horizontal de banda Lea este Instructivo por completo antes de usar la herramienta...

Страница 2: ...na o se cruce cuando est en funcionamiento 12 No extienda su radio de acci n Evite toda postura que cause cansancio Cuide de que su posici n sea segura y de que conserve el equilibrio 13 Mantenga las...

Страница 3: ...a una operaci n segura Instale una v lvula sin retorno o de corte en la tuber a de entrega si el compresor se acoplar en paralelo con otro compresor o si se conectar a un sistema de suministro de aire...

Страница 4: ...LIDA 6 5 mm L TANQUE M MAN METRO DE TANQUE N LLANTAS O V LVULA DE PURGA P BOT N DE INTERRUPTOR Q PROTECTOR DE SOBRECARGA ACCESORIOS 1 Botella de aceite 2 Filtros de aire 1 Tap n del dep sito de aceite...

Страница 5: ...antenimiento preventivo diario ACEITE Revise el nivel del aceite del c rter y rellene de ser necesario Si su compresor no se usa diariamente revise el nivel de aceite del c rter antes de arrancarlo Ca...

Страница 6: ...a con un protector termomagn tico que evita que el motor sufra un calentamiento excesivo El motor se apaga cuando se activa el interruptor Fig L para restablecer el motor siga los siguientes pasos 1 P...

Страница 7: ...ompresor ha operado durante un periodo considerable en un lugar h medo 1 Es necesario drenar el tanque 2 Fugas de aire en la tuber a en la m quina o en el sistema externo 3 Fugas en la v lvula de segu...

Страница 8: ...eemplazar la v lvula acuda a un CSAT 1 Revise la tensi n de la l nea de alimentaci n los fusibles o corrija la sobrecarga del motor 2 Consulte a un electricista calificado 1 Cambie y use el aceite cor...

Страница 9: ...SUCURSAL GUADALAJARA AV ADOLFO B HORN 6800 COL SANTA CRUZ DEL VALLE C P 45655 TLAJOMULCO DE ZU IGA JAL TEL 01 33 3606 5285 AL 90 MICHOAC N FIX FERRETER AS AV PASEO DE LA REP BLICA 3140 A COL EX HACIEN...

Страница 10: ...s recomendadas o no se haya operado de acuerdo al instructivo o haya sido alterado o reparado por personal no autorizado por Para hacer v lida la garant a o adquirir piezas y componentes deber present...

Страница 11: ...19365 Horizontal belt drive air compressor Manual IMPORTANT NOTICE This product should not be exposed to liquids dripping or splashing Read the user s manual thoroughly before operating this tool CAU...

Страница 12: ...ing one hand and enables to use both hands Keep proper footing and balance at all times Do not overreach over or walk across the tool when is running 12 Do not extend your range of action Avoid a stan...

Страница 13: ...valve in the inlet piping in case compressor shall be parallel coupled with a second compressor or if it will be connected to an air supply system Double check all piping and hoses connected to the c...

Страница 14: ...URGE VALVE P SWITCH BUTTON Q THERMAL OVERLOAD PROTECTOR ACCESSORIES 1 Oil Bottle 2 Air Filters 1 Oil Deposit Cap 4 Wheels 4 Rondanas 4 Cotter pins BEFORE CONNECTING THE COMPRESSOR VERIFY THE FOLLOWING...

Страница 15: ...ciency for a long period of time Preventive daily maintenance OIL Check oil level in the casing and refill if necessary If the compressor is not used every day check the oil level in the casing before...

Страница 16: ...or is built with a thermal magnetic protector that prevents the motor from excessive heating The engine shuts down when the switch is activated See figure L to reset the engine follow these steps 1 Pr...

Страница 17: ...rating in a damp place for a long period of time 1 Draining the tank is necessary 2 Air leaks in pipeline in the machine or the external system 3 Leaks in the tank security valve 1 There is a possibil...

Страница 18: ...a TASC 1 Double check feeding line voltage the fuses or correct the motor overload 2 Consult with a qualified electrician 1 Change and use the right type of oil 2 Add oil to the casing up to the righ...

Страница 19: ...GUADALAJARA AV ADOLFO B HORN 6800 COL SANTA CRUZ DEL VALLE C P 45655 TLAJOMULCO DE ZU IGA JAL TEL 01 33 3606 5285 AL 90 MICHOAC N FIX FERRETER AS AV PASEO DE LA REP BLICA 3140 A COL EX HACIENDA DE LA...

Страница 20: ...0 CDMX Mex or at the store where you bought it or at a service center listed in the attached warranty policy and or at www truper com Transportation costs resulting from compliance of this warranty wi...

Отзывы: