![Truper 17332 Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/truper/17332/17332_manual_1176565021.webp)
15
16
110V
E
B
7
Installation
C
Torch
Power Supply
Compressor
50 PSI - 80 PSI
Moist
filter
To prevent electric shock read the
information in the “Power Requirements” section in pages 3
and 5.
• Connect the power cable (
E
) to the 220 V work voltage.
Before using, the equipment shall be
correctly grounded. No not remove the ground cable.
Otherwise it causes severe body injuries.
Make sure the torch is
correctly assembled before connecting into the
equipment.
• Assemble all the torch parts in the same order
as shown in the graph.
• When it is assembled connect the torch to the
front panel terminal (
A
).
• Unroll the torch hose completely.
WARNING
D
A
Compressed Air Supply
• The plasma cutter requires a
50 PSI - 80 PSI air compressor.
• Use a moisture filter between the
compressor and the plasma cutter to send totally dry air to
the torch. Otherwise, the cut quality will be seriously
diminished.
• Connect the air-line of the moist filter to the cutter air inlet
in the back panel of the plasma cutter (
D
).
CAUTION
CAUTION
CAUTION
CAUTION
• Insert the grounding clamp fast connection. Turn one
quarter of a turn in a clockwise direction to secure it in
the front panel terminal (
B
).
• Connect the ground clamp (
C
) to the piece or work
bench.
If the ground clamp is not making contact
correctly, the piece will not get cut because the cutter
will only be operating with the pilot flame.
NOTE
Grounding Clamp
ENGLISH