![Truper 17332 Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/truper/17332/17332_manual_1176565017.webp)
33
17332
Code
Description
COPLA-60X
Voltage
Power Cord Grips used is: Type “Y”.
Tool Build Quality: Basic Insulation
Thermal insulation on motor winding: Class H
OUTPUT
INPUT
Current
49 A
Frequency
60 Hz
Plasma Cutter
220 V
50 PSI - 80 PSI
IP21S
IP Grade
Current Range
305 V c.c.
Open Circuit Voltage
1”
Maximum Cutting Capacity
Air Pressure
31,74 lb
Weight
3/4”
Ideal Cutting Capacity
Work Cycle
Insulation
Class I
20 A - 60 A
3G - 6 mm
2
with 221 °F insulation
Conductors
30 % 3 minutes’ work per 7 minutes’ rest.
The specified output values are given in a 68 °F temperature. With higher temperatures, the work cycle can be reduced.
Power Requirements
Technical specifications
ENGLISH
WARNING
WARNING
Avoid the risk of electric shock or severe injury. When the power cable gets damaged
it should only be replaced by the manufacturer or at a Authorized Service Center.
The build quality of the electric insulation is altered if spills or liquid gets into the tool while in use.
Do not expose to rain, liquids and/or dampness.
Before gaining access to the terminals all power sources should be disconnected.
The tool shall be grounded while in use to prevent an electric shock.
The cutter shall be installed as close as possible to the mains power supply. Check the power supply carries the same
voltage than the one indicated in the motor nameplate.
This tool has to be grounded.
The power cables are coded with the following colors:
• - If using the cutter together with more tools having the same ground, connect in parallel, never making a series.
• The ground conductor cable gauge shall not be a lower gauge than the power supply cable.
• Connection to the power supply shall be carried out by a professional electrician.
• Double check the input connection voltage shown in the plasma cutter nameplate matches the power
supply voltage.
• The power supply gauge shall comply with the following requirements
CAUTION
CAUTION
CAUTION
* Fuse fusion current is double than its rated current.
Fuse (rated working current)
Electric Wire
55 A (*)
6 mm
2
CAUTION
CAUTION
GREEN GROUND
WHITE CURRENT
BLACK CURRENT
WARNING
WARNING