28
Perform the rest of the installation as shown in the instal-
lation instructions supplied with your device.
+ Battery
ON
Remove /
insert key
OFF
+ Control unit
Ø 25 mm
– +
Battery isolating switch
Control unit
Mover®
Mover®
Battery
≥10 mm²
Fig. 5: Installation of battery isolating switch and battery
connections
Wiring diagram
Always install the fuses close to the positive terminal of
the battery!
* The fuses
(not included in the
delivery) only serve
to protect the line.
BU = blue,
RD = red
Battery
Battery
Battery sense
B+
Ready
Liquid
Gel / A
GM
Temp. sensor
Battery
1
2 A*
RD 0.75 mm²
30 A*
RD 6 mm²
BU 6 mm²
≥10 mm²
12 V
Temperature sensor of the battery
Fig 6: Wiring diagram