IMPELLER (2)
Refer to Fig. 43 for Steps 1 thru 4.
1
Inspect impeller vanes for damage. Replace if grooved
deeper than
NOTE: When clearances between the rings become
excessive (increase by 50%), hydraulic performance
decreases substantially.
Table 5 — Diametrical Clearance (in)
Pump Size
Impeller Wear Ring
Pressure
Reducing
Sleeves
Center Impeller Rings
Truflo Standard
API 610
Ring Diameter
Truflo
Standard
Truflo Standard
3x4-8B
0.010
0.015
4.00
0.010
0.030
0.016
4.87
0.017
5.50
3x6-9/10
0.010
0.015
4.01
0.010
0.030
0.017
5.22
0.018
6.60
4x6-10/D
0.011
0.015
4.24
0.010
0.030
0.017
5.97
0.018
6.52
4x6-11/D
0.010
0.016
4.61
0.010
0.030
0.018
6.48
0.019
7.36
6x8-11A/B
0.010
0.017
5.74
0.010
0.030
0.019
7.86
0.020
8.48
6x8-13D
0.010
0.017
5.74
0.010