Ember protection:
In CANADA
, Combustible floor in front of the fireplace insert must be protected from hot embers by non-
combustible material extending 18”(450mm) to the front/firing side and 8” (200mm) to sides of the unit.
Consult CAN/CSA-B365 Installation Code for Solid-Fuel-Burning appliances and equipment in Canada,
18”
450mm
Non-combustible
Fireplace Hearth
*
Non-combustible
Ember Protection
MINIMUM EMBER
PROTECTION
DIMENSIONS
22 7/8”
581mm
Fireplace Hearth requirements
In Canada -
The Masonry Fireplace’s Hearth must extend a minimum of 16”(406mm) in front and 8”(203mm)
beyond each side of the fireplace opening and can be flush with adjacent combustible floor.
In the U.S
. - the Masonry Fireplace’s Hearth must extend a minimum of 16” in front and 8” beyond each side
of the fireplace opening and be raised 1” above a combustible floor,
or
the hearth must extend a minimum of
21”in front and 8” beyond each side of the fireplace opening and can be flush with a combustible floor.
Non-combustible
Fireplace Hearth
**Non-combustible
Ember Protection
Non-combustible
hearth
16”
16”
21”
Flooring
Flooring
Min. 1” drop
**
Ember protection:
Combustible floor in front of the fireplace insert must be protected from hot embers by non-combustible
material extending 16”(457mm) in the U.S. to the front/firing side and 8” to sides of the unit.
Consult N.F.P.A. 211 Standard for chimneys, fireplaces, vents and Solid-Fuel-Burning appliances in USA.
16”
406mm
Figure4:flush ember protection TRNO 20 insert.
Figure5:US 2in Drop hearth TRNO 20 insert
Figure6:US flush hearth TRNO 20 insert