Problem Cause 

Cure

Glass is Dirty 

1.  Wood is wet 

- Use dry wood

 

2. Turning down air control 

- Do not turn down until

 

     or damper too soon 

a) there is a good bed of coals 

 

  

b) the wood is charred

 

3. Draft too low 

- Improper chimney height and / or diameter 

 

  

- Chimney plugged or restricted, check flue 

 

  

- Provide outside air for combustion

 

4. Door gasket leakage 

- Replace gasket 

 

  

- Check latch - If bent, consult dealer.

Excessive Creosote Buildup - See 1, 2, 3, above.

Low Heat Output 

1. Wood is wet 

- Use dry wood

 

2. Fire too small 

- Build a larger fire

 

3. Draft too low 

- Chimney plugged or restricted, inspect and  

 

 

  

   clean

Won't Burn Overnight 

1. Air control is set too high 

- Set control lower

 

2. Not enough wood 

- Unsplit wood is preferred for overnight burns

 

3. Draft too high 

- Excessive chimney height and/or diameter,

 

  

  See "Proper Draft" on page 9.

Stove Won't Burn 

1. Combustion air supply 

- Check outside air supply for obstruction 

 

     blocked 

- Check that room air cover is removed

 

2. Draft too low 

- Chimney plugged or restricted, inspect and 

 

 

  

 

clean

        - 

Chimney 

oversized 

or 

otherwise 

unsuitable,

         

 

 

consult 

Dealer

 Troubleshooting 

Содержание TN20 INSERT

Страница 1: ...y follow the installation instructions Contact local building or fire officials about restrictions and installation inspection requirements in you area IMPORTANT THESE INSTRUCTIONS ARE TO REMAIN WITH...

Страница 2: ...m heater Failure to follow instructions may result in property damage bodily injury or even death HOT GLASS WILL CAUSE BURNS DO NOT TOUCH GLASS UNTIL COOLED NEVER ALLOW CHILDREN TO TOUCH GLASS WARNING...

Страница 3: ...udes the energy required to vaporize the water in the fuel 3 The range of BTU outputs is based on efficiency using CSA B415 Performance testing of solid fuel burning heating appli ances and burn rates...

Страница 4: ...fiberglass rope requires only light pressure to seal This will prolong seal life It is important that the door seal be main tained in good condition Periodically inspect seals and replace if necessar...

Страница 5: ...damage listed above Continuing to operate your stove with broken parts may accelerate damage to other parts and will void your warranty Blower The blower should be cleaned out a minimum every six mont...

Страница 6: ...ult for the tars and gases to ignite thus creating dense smoke and poor combustion This moisture laden smoke cools the chimney compounding the problem In summary a certain amount of creosote is inevit...

Страница 7: ...properly air dried seasoned for six months or more Wet or unseasoned wood will cause the fire to smoulder and produce large amounts of smoke and creosote Wet wood also pro duces very little heat and...

Страница 8: ...ieces of dry wood on top 3 Ignite the paper and leave the door ajar approximately 1 2 13mm 1 25mm until the wood kindling is fully engulfed in flame DO NOT LEAVE UNATTENDED 4 After the kindling is ful...

Страница 9: ...azardous and may void the manufacturer s warranty Too slow a burn may contribute to creosote buildup and lowers com bustion efficiency Heat Output Experience will give you the right settings for prope...

Страница 10: ...t fitting lid The closed container of ashes should be placed outside on a non combustible floor or on the ground well away from all combustible materials pend ing final disposal If the ashes are dispo...

Страница 11: ...side of stove Mantel Top Facing Measured from firebox top 15 in 380 mm Ceiling From base of the unit 54 in 1 37m Mantel or Top Facing Side Facing Hearth Adjacent Wall SIDE FACING AND ADJACENT WALL ME...

Страница 12: ...combustible floor In the U S the Masonry Fireplace s Hearth must extend a minimum of 16 in front and 8 beyond each side of the fireplace opening and be raised 1 above a combustible floor or the hearth...

Страница 13: ...standards Warning Under no circumstances is this heater to be installed in a makeshift or temporary manner It may be fired only after the following conditions have been met DO NOT CONNECT THIS UNIT TO...

Страница 14: ...damper is to be locked open or removed completely Have the chimney cleaned to pre vent odours and possible fires WARNING Do not remove bricks or mortar from your existing fireplace Exception Masonry o...

Страница 15: ...re place and attach the connector to the stove collar and secure with screws Use the rear adjusting legs to level the Insert 5 Measure trim and shape a top flashing to fit the existing chimney flue Pl...

Страница 16: ...eat circulator 5 Alteration of the fireplace in any manner is not permitted with the following exceptions a external trim pieces which do not affect the operation of the fireplace may be removed and s...

Страница 17: ...Insert in one of two ways 1 Outside air supply Remove cover from ash clean out in existing fireplace Place a rodent screen in place of the cover Install the Insert as described in the Installation sec...

Страница 18: ...d assembly to the upright position and make sure the front face is flat and even at the joints Shipping screw Surround Assembly and Installation 4 Move the assembled surround around the stove Locate a...

Страница 19: ...t one half of baffle board above the two back baffle tubes inside the firebox slide over to the right and allow to rest on the baffle air assembly 2 Ensure that the second half is inserted to allow th...

Страница 20: ...5 Mounting bolts Blower Figure14 surround removal Blower Maintenance Removal The blower requires annual cleaning to remove buildup on the blades More frequent cleaning may be required if room conditio...

Страница 21: ...or in the absence of local codes with the current CSA C22 1 Canadian Electrical Code and in the USA with the National Electrical Code ANSI NFPA 70 latest edition Blower Fan controller Ground power cor...

Страница 22: ...rick rail Figure 16 and slide it to either the far left or far right Figure 19 2 Place 3 more bricks up under the rear brick rail to complete the rear brick placement Figure 19 3 Place the floor brick...

Страница 23: ...e Creosote Buildup See 1 2 3 above Low Heat Output 1 Wood is wet Use dry wood 2 Fire too small Build a larger fire 3 Draft too low Chimney plugged or restricted inspect and clean Won t Burn Overnight...

Страница 24: ...80002138 4 Rear Brick Rail 80002143 5 Door Casting Assy No Glass c w Handle 80000621 6 Door and Glass Gasket 80000600 7 Replacement Glass c w clamps gasket 80000616 8 4pc Glass Clamps c w screws 8000...

Страница 25: ...LDUP MAY OCCUR RAPIDLY OPERATE ONLY WITH FEED DOOR CLOSED OPEN TO FEED FIRE ONLY STOVE DESIGNED TO BURN CORDWOOD ONLY BURNING OTHER MATERIALS MAY CAUSE DAMAGE TO STOVE OR HOME THIS WOOD HEATER NEEDS P...

Страница 26: ...26 TN 20B INSERT 110618 28 PACIFIC ENERGY FIREPLACE PRODUCTS LTD...

Страница 27: ...110618 28 TN 20B INSERT 27 PACIFIC ENERGY FIREPLACE PRODUCTS LTD Printed in Canada...

Страница 28: ...port please contact your retailer Web site www truenorthstoves com 2975 Allenby Rd Duncan BC V9l 6V8 2018 Copyright Pacific Energy Fireplace Products LTD Reproduction adaptation or translation without...

Отзывы: