110618-28
TN 20B INSERT
15
©PACIFIC ENERGY FIREPLACE
PRODUCTS LTD.
Full Flue Liner - (Required in Canada)
A listed stainless steel rigid or flexible liner extends
from the Insert flue collar to the top of the chimney.
In Canada, this Fireplace Insert must be installed
with a continuos chimney liner of 6 inch diameter
extending from the Fireplace Insert to the top of the
chimney. The chimney liner must conform to the
class 3 requirements of CAN/ULC-B365, Standard for
Lining Systems for Existing Masonry or Factory-Built
Chimneys and Vents, or CAN/ULC-S640, Standard
for Lining Systems for New Masonry Chimneys.
1)
Measure the chimney height from the top of
the existing flue to the floor of the hearth. This will
allow extra length of liner for flashing and rain cap.
2)
Feed the stainless steel liner from top of the
chimney, through the damper area and into the fire-
place cavity.
3)
Attach a stove connector to the bottom of the
liner, as per the instructions provided with the chim-
ney liner.
4)
Push the Insert into position inside the fire-
place and attach the connector to the stove collar
and secure with screws. Use the rear adjusting legs
to level the Insert.
5)
Measure, trim and shape a top flashing to
fit the existing chimney flue. Plan for a 1” to 1-1/2”
overlap on each side. Place flashing over top of the
liner and seat firmly against the tile. Screw flashing
collar to liner. Caulk gap around flashing with RTV
silicone.
6)
Attach a rain cap to the end of the liner. A
storm collar may be used if desired.
Rain Cap
6” Stainless Steel
Rigid or Flex Liner
Full Flue Liner
Mantel or
Top Facing
The Insert must be installed in accordance with local and or national building codes. The two methods of flue
connection that are acceptable in most areas are shown on page 15 and 16.
A metal tag is provided and is to be fastened to the back wall of the fireplace, if the fireplace has been modi-
fied to accommodate the insert.
Pacific Energy highly recommends the use of a full liner as the safest installation and providing optimum per-
formance. When connected to a full liner, the Insert is able to draft correctly and will help prevent problems
such as difficult start-ups and smoking out the door.
Consult your local Dealer about codes and installation.
Figure8:Fulliner TRNO