Full Flue Liner - (Required in Canada)

A listed stainless steel rigid or flexible liner extends 
from the Insert flue collar to the top of the chimney.

In Canada, this Fireplace Insert must be installed 
with a continuos chimney liner of 6 inch diameter 
extending from the Fireplace Insert to the top of the 
chimney. The chimney liner must conform to the 
class 3 requirements of CAN/ULC-B365, Standard for 
Lining Systems for Existing Masonry or Factory-Built 
Chimneys and Vents, or CAN/ULC-S640, Standard 
for Lining Systems for New Masonry Chimneys.

1) 

Measure the chimney height from the top of 

the existing flue to the floor of the hearth.  This will 
allow extra length of liner for flashing and rain cap.

2) 

Feed the stainless steel liner from top of the 

chimney, through the damper area and into the fire-

place cavity.

3) 

Attach a stove connector to the bottom of the 

liner, as per the instructions provided with the chim-
ney liner.

4) 

Push the Insert into position inside the fire-

place and attach the connector to the stove collar 
and secure with screws.  Use the rear adjusting legs 
to level the Insert.

5) 

Measure, trim and shape a top flashing to 

fit the existing chimney flue.  Plan for a 1” to 1-1/2” 
overlap on each side.  Place flashing over top of the 
liner and seat firmly against the tile.  Screw flashing 
collar to liner.  Caulk gap around flashing with RTV 
silicone.

6) 

Attach a rain cap to the end of the liner.  A 

storm collar may be used if desired.

Rain Cap

6” Stainless Steel

Rigid or Flex Liner

Full Flue Liner

Mantel or

Top Facing

The Insert must be installed in accordance with local and or national building codes.  The two methods of flue 
connection that are acceptable in most areas are shown on page 15 and 16.

A metal tag is provided and is to be fastened to the back wall of the fireplace, if the fireplace has been modi-
fied to accommodate the insert.
Pacific Energy highly recommends the use of a full liner as the safest installation and providing optimum per-
formance.  When connected to a full liner, the Insert is able to draft correctly and will help prevent problems 
such as difficult start-ups and smoking out the door.

Consult your local Dealer about codes and installation.

Figure8:Fulliner TRNO

Содержание TN20 INSERT

Страница 1: ...y follow the installation instructions Contact local building or fire officials about restrictions and installation inspection requirements in you area IMPORTANT THESE INSTRUCTIONS ARE TO REMAIN WITH...

Страница 2: ...m heater Failure to follow instructions may result in property damage bodily injury or even death HOT GLASS WILL CAUSE BURNS DO NOT TOUCH GLASS UNTIL COOLED NEVER ALLOW CHILDREN TO TOUCH GLASS WARNING...

Страница 3: ...udes the energy required to vaporize the water in the fuel 3 The range of BTU outputs is based on efficiency using CSA B415 Performance testing of solid fuel burning heating appli ances and burn rates...

Страница 4: ...fiberglass rope requires only light pressure to seal This will prolong seal life It is important that the door seal be main tained in good condition Periodically inspect seals and replace if necessar...

Страница 5: ...damage listed above Continuing to operate your stove with broken parts may accelerate damage to other parts and will void your warranty Blower The blower should be cleaned out a minimum every six mont...

Страница 6: ...ult for the tars and gases to ignite thus creating dense smoke and poor combustion This moisture laden smoke cools the chimney compounding the problem In summary a certain amount of creosote is inevit...

Страница 7: ...properly air dried seasoned for six months or more Wet or unseasoned wood will cause the fire to smoulder and produce large amounts of smoke and creosote Wet wood also pro duces very little heat and...

Страница 8: ...ieces of dry wood on top 3 Ignite the paper and leave the door ajar approximately 1 2 13mm 1 25mm until the wood kindling is fully engulfed in flame DO NOT LEAVE UNATTENDED 4 After the kindling is ful...

Страница 9: ...azardous and may void the manufacturer s warranty Too slow a burn may contribute to creosote buildup and lowers com bustion efficiency Heat Output Experience will give you the right settings for prope...

Страница 10: ...t fitting lid The closed container of ashes should be placed outside on a non combustible floor or on the ground well away from all combustible materials pend ing final disposal If the ashes are dispo...

Страница 11: ...side of stove Mantel Top Facing Measured from firebox top 15 in 380 mm Ceiling From base of the unit 54 in 1 37m Mantel or Top Facing Side Facing Hearth Adjacent Wall SIDE FACING AND ADJACENT WALL ME...

Страница 12: ...combustible floor In the U S the Masonry Fireplace s Hearth must extend a minimum of 16 in front and 8 beyond each side of the fireplace opening and be raised 1 above a combustible floor or the hearth...

Страница 13: ...standards Warning Under no circumstances is this heater to be installed in a makeshift or temporary manner It may be fired only after the following conditions have been met DO NOT CONNECT THIS UNIT TO...

Страница 14: ...damper is to be locked open or removed completely Have the chimney cleaned to pre vent odours and possible fires WARNING Do not remove bricks or mortar from your existing fireplace Exception Masonry o...

Страница 15: ...re place and attach the connector to the stove collar and secure with screws Use the rear adjusting legs to level the Insert 5 Measure trim and shape a top flashing to fit the existing chimney flue Pl...

Страница 16: ...eat circulator 5 Alteration of the fireplace in any manner is not permitted with the following exceptions a external trim pieces which do not affect the operation of the fireplace may be removed and s...

Страница 17: ...Insert in one of two ways 1 Outside air supply Remove cover from ash clean out in existing fireplace Place a rodent screen in place of the cover Install the Insert as described in the Installation sec...

Страница 18: ...d assembly to the upright position and make sure the front face is flat and even at the joints Shipping screw Surround Assembly and Installation 4 Move the assembled surround around the stove Locate a...

Страница 19: ...t one half of baffle board above the two back baffle tubes inside the firebox slide over to the right and allow to rest on the baffle air assembly 2 Ensure that the second half is inserted to allow th...

Страница 20: ...5 Mounting bolts Blower Figure14 surround removal Blower Maintenance Removal The blower requires annual cleaning to remove buildup on the blades More frequent cleaning may be required if room conditio...

Страница 21: ...or in the absence of local codes with the current CSA C22 1 Canadian Electrical Code and in the USA with the National Electrical Code ANSI NFPA 70 latest edition Blower Fan controller Ground power cor...

Страница 22: ...rick rail Figure 16 and slide it to either the far left or far right Figure 19 2 Place 3 more bricks up under the rear brick rail to complete the rear brick placement Figure 19 3 Place the floor brick...

Страница 23: ...e Creosote Buildup See 1 2 3 above Low Heat Output 1 Wood is wet Use dry wood 2 Fire too small Build a larger fire 3 Draft too low Chimney plugged or restricted inspect and clean Won t Burn Overnight...

Страница 24: ...80002138 4 Rear Brick Rail 80002143 5 Door Casting Assy No Glass c w Handle 80000621 6 Door and Glass Gasket 80000600 7 Replacement Glass c w clamps gasket 80000616 8 4pc Glass Clamps c w screws 8000...

Страница 25: ...LDUP MAY OCCUR RAPIDLY OPERATE ONLY WITH FEED DOOR CLOSED OPEN TO FEED FIRE ONLY STOVE DESIGNED TO BURN CORDWOOD ONLY BURNING OTHER MATERIALS MAY CAUSE DAMAGE TO STOVE OR HOME THIS WOOD HEATER NEEDS P...

Страница 26: ...26 TN 20B INSERT 110618 28 PACIFIC ENERGY FIREPLACE PRODUCTS LTD...

Страница 27: ...110618 28 TN 20B INSERT 27 PACIFIC ENERGY FIREPLACE PRODUCTS LTD Printed in Canada...

Страница 28: ...port please contact your retailer Web site www truenorthstoves com 2975 Allenby Rd Duncan BC V9l 6V8 2018 Copyright Pacific Energy Fireplace Products LTD Reproduction adaptation or translation without...

Отзывы: