Ember Protection
The stove may be installed on a combustible floor, provided ember protection made from a non-combustible
material (a minimum K value of 23.7 btu/ft h °F /the equivalent of 20 Gauge steel) is used.
UL 1618 type 1 protection
This protection must extend as follows:
In Canada: 18" (457 mm) from the loading door on the firing side and 8" (203 mm) from the sides. See Figure
3, below.
In USA: 16" (406 mm) to the front of the firebox and 8" (203 mm) from the sides of the fuel loading door
opening. See Figure 4, below. This protection is also required under the chimney connector and 2" (51 mm)
beyond each side.
Securing Bracket Installation:
These will be needed to anchor the stove in a
mobile home installation and are recommended
when installing combustion air to prevent move-
ment of the unit and separation of the combustion
air intake.
1. The hold down brackets are provided in a bag
with the unit. Insert the brackets by sliding
them through the slots in the rear legs. Then lag
the bracket to the floor or hearth pad.
Minimum Width - 37 3/8"(949mm)
Minimum Overall Depth - 40"(1.02m)
Non-combustible
oor protector
8" [203mm]
18" [457mm]
8" [203mm]
8" [203mm]
Canada Only
Figure 3: TN10 - CAN Floor protector.
Minimum Width - 28 3/8"(721mm)
Minimum Overall Depth - 29 1/2"(750 m m)
Non-combustible
Ember protector
3 1/2” [89mm]
16" [406mm]
3 1/2" [89mm]
United States Only
Figure 4: TN10 - US Floor protector.
Figure 5: Securing bracket.