Residential Clearances
•
BOTH CHIMNEY SYSTEM AND CONNECTOR MUST BE 6"(150mm) DIAMETER AND LISTED TO:
CANADA - CONNECTOR - LISTED to ULC S-641 and CHIMNEY LISTED to ULC-S-629
USA - CONNECTOR AND CHIMNEY LISTED to UL-103 HT
1. Residential Clearances to Combustible surfaces and materials;
This heater may be installed using a single-wall connector (smoke pipe) as per local and National fire and
Installation codes. See
Single wall Connector
in Figure 3. Clearances may be reduced with various heat
shielding or insulating materials. Consult national fire codes and authorities for approval ( U.S. -NFPA 211
or CAN. - CSA B365)
For for close clearances, use a listed double-wall connector, See Figure 2. "Double Wall Connector".
2. Mobile Home installation must use listed double-wall connector, For installation in a mobile home, see
clearances in Figure 8 on page 19.
Crate Removal
1. Carefully remove wood top and supports.
2. Remove plastic cover.
•
Remove the retaining clip on the front of the baffle before lighting for the first time
13 1/4"
336mm
8"
205mm
18 5/8”
475mm
16 1/4"
413mm
6"
152mm
11 1/4"
286mm
6"
155mm
13 1/4"
337mm
3"
76mm
6"
152mm
3"
76mm
8"
205mm
8"
205mm
18 5/8"
475mm
8"
205mm
11 1/4"
286mm
6"
155mm
18 5/8"
475mm
8"
205mm
Minimum Clearance to Combustibles
Alcove: Min. Height 5' / 1.525m
Max. Depth 3' / 915mm
Single Wall Connector - Residential
Double Wall Connector - Residential
Figure 2: TN10 clearances.