Press the
〈
OK
〉
button to begin the standard count. After taking the
standard count, the gauge software displays the results, as shown in
Figure 4–3.
Troxler recommends that the operator keep a daily log of the
standard counts (see
). To verify gauge stability,
compare the daily standard count to a reliable reference as follows:
♦
During the first four days of operation of a new or recalibrated
gauge, compare the daily standard count to the factory-
calibrated values.
♦
After the first four days of operation (or after taking four
standard counts), compare the daily standard count to the
average of the last four counts. Acceptable standard count limits
are:
±
1% each day for DS1 (density standard),
±
1.3% each day for DS2 (density standard), and
±
2% each day for MS (moisture standard).
If the standard count
passes
, record the standard counts, then
press the
〈
Yes
〉
button. The PDA displays the prompt
Do you
wish to erase the last four standard counts?
Press
〈
No
〉
. The PDA displays
Standard counts have been
stored.
Press the
〈
ok
〉
button to return to the
Standard
Menu
.
If the standard count
fails by less than 10%
and it has been
more
than a month
since the last standard count, then accept the
standard count by pressing the
〈
Yes
〉
button. At the
Do you
wish to erase the last four standard counts?
prompt,
press the
〈
Yes
〉
button. The PDA displays
Standard counts
have been stored. Previous four standard counts were
erased from memory.
Press the
〈
ok
〉
button to return to the
Standard Menu
. Take
four additional standard counts. The last of these counts will be
compared to the previous four, and the standard counts should
pass. If not, repeat the procedure. If it still fails, perform a stat
test (see page C–2) and a drift test (see page C–5), then contact
your Troxler representative.
Содержание Enhanced RoadReader Plus 3451
Страница 7: ...Model 3451 vii NOTES...
Страница 17: ...xvi NOTES...
Страница 29: ...1 12 NOTES...
Страница 33: ...2 4 Figure 2 1 Effect of Moisture on Depth of Measurement...
Страница 85: ...4 22 NOTES...
Страница 106: ...Model 3451 6 3 Figure 6 1 Offset Menu 6 OFFSETS CALIBRATION...
Страница 114: ...Model 3451 6 11 Figure 6 10 Moisture Offset Erase Prompt 6 OFFSETS CALIBRATION...
Страница 127: ...6 Figure 6 25 Enter File Name Figure 6 23 Input True Density Figure 6 24 Thin Layer Special Calibration Results...
Страница 131: ...6 NOTES...
Страница 141: ...7 10 Figure 7 5 Project Data Spreadsheet...
Страница 145: ...7 14 Figure 7 8 Project Setup Display Figure 7 9 Standard Counts Display...
Страница 147: ...7 16 Figure 7 10 Project Status Display Figure 7 11 Source Decay Display...
Страница 149: ...7 18 Figure 7 12 Stat Test Display Figure 7 13 Drift Test Display...
Страница 153: ...7 22 NOTES...
Страница 166: ...Model 3451 Appendix A 13 Figure A 3 Cleaning the Sliding and Fixed Blocks...
Страница 174: ...Model 3451 Appendix A 21 NOTES...
Страница 175: ......
Страница 183: ...Appendix B 8 NOTES...
Страница 187: ...Figure C 5 Review Stat Test Appendix C 4 Figure C 3 View Stat Counts Figure C 4 Stat Test Results...
Страница 221: ...Appendix D 6 NOTES...
Страница 223: ...Appendix E 2 STANDARD COUNT LOG Gauge Serial Number Date Moisture MS Density DS1 Density DS2...
Страница 225: ...Appendix E 4 STANDARD COUNT LOG Gauge Serial Number Date Moisture MS Density DS1 Density DS2...
Страница 227: ...Appendix E 6 STANDARD COUNT LOG Gauge Serial Number Date Moisture MS Density DS1 Density DS2...
Страница 229: ...Appendix E 8 STANDARD COUNT LOG Gauge Serial Number Date Moisture MS Density DS1 Density DS2...
Страница 235: ...Appendix G 4 NOTES...
Страница 246: ...Model 3451 Warranty 1 NOTES WARRANTY...