EN
9
deep well pump TDP 370 E / TDP 750 E
Operation
Switching the device on
Once you have completely installed the device as described in
the Start-up chapter, you can switch it on.
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
Note
Please note that the device is designed for
max.
40
switch-on/switch-off operations per hour.
Before every restart, wait for at least 3 minutes.
1. Plug the mains plug into a sufficiently fused mains socket.
2. After switch-on, regularly check whether the device
operates correctly. Turn off the power supply if after start-
up of the motor the pump shows an unusual operational
behaviour (such as strong vibrations at the pump or
pressure line, a fluctuating flow rate or similar). If you
leave the device unattended for a longer period of time,
interrupt the device's power supply.
Switching the device off
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
1. Hold onto the mains plug (
6
) while pulling the power cable
out of the mains socket.
Shutdown
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
1. Hold onto the mains plug while pulling the power cable out
of the mains socket.
2. Pull the device out of the pumping medium by means of
the cord or rope.
3. Disconnect the pressure line.
4. Clean the device according to the Maintenance chapter.
5. Store the device according to the Storage chapter.
Available accessories
Warning
Only use accessories and additional equipment
specified in the instructions.
Using insertion tools or accessories other than those
specified in the instructions may cause a risk of injury.
Accessories
Article number
TDP DSP (with plug)
4.610.000.291
TDP DS (without plug)
4.610.000.290
Errors and faults
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
Warning of electrical voltage
Tasks which require the housing to be opened
must only be carried out by authorised specialist
companies or by Trotec.
•
Switch off the device.
•
Hold onto the mains plug while pulling the power cable out
of the mains socket.
The device has been checked for proper functioning several
times during production. If malfunctions occur nonetheless,
check the device according to the following list.
The device does not start:
•
Check the power connection.
•
Check the power cable and mains plug for damage.
•
Check the on-site fusing.
•
The device might have overheated and the thermal
protection circuit is activated.
If so, wait for approx. 10 minutes before restarting the
device. If the device is not starting, have the electrics
checked by a specialist company or by Trotec.
•
The water temperature is above 35 °C and the thermal
protection circuit is activated.
Содержание TDP 370 E
Страница 1: ...TRT BA TDP370E TDP750E TC2020 12 001 EN TDP 370 E TDP 750 E EN ORIGINAL INSTRUCTIONS DEEP WELL PUMP...
Страница 13: ...EN 13 deep well pump TDP 370 E TDP 750 E Wiring diagram TDP 370 E TDP 750 E...
Страница 14: ...14 EN deep well pump TDP 370 E TDP 750 E Exploded assembly drawing...
Страница 17: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...