deep well pump TDP 370 E / TDP 750 E

Device may start up without warning

This symbol indicates dangers to the life and health of
persons due to electrical voltage.

Device may start up without warning

This symbol indicates that the device may start up
without warning when it is switched on.

General warning sign

This symbol indicates that you must be aware of the
dangers that can occur when working with the device.

Do not use damaged power cables or mains plugs

This symbol indicates that the device must no longer be
operated if the power cable is damaged.

Pull the mains plug

This symbol indicates that the mains plug must be
removed from the socket when the device is not in use.

Device may start up without warning

Information marked with this symbol indicates that the
instructions must be observed.

Residual risks

Warning of electrical voltage

Work on the electrical components must only be
carried out by an authorised specialist company!

Warning of electrical voltage

Before any work on the device, remove the mains plug
from the mains socket!
Hold onto the mains plug while pulling the power cable
out of the mains socket.

Warning

Dangers can occur at the device when it is used by
untrained people in an unprofessional or improper way!
Observe the personnel qualifications!

Warning

The device is not a toy and does not belong in the
hands of children.

Warning

Risk of suffocation!
Do not leave the packaging lying around. Children may
use it as a dangerous toy.

Note

If you store or transport the device improperly, the
device may be damaged.
Note the information regarding transport and storage of
the device.

Behaviour in the event of an emergency

1. Switch off the device.
2. In an emergency, disconnect the device from the mains

feed-in: Hold onto the mains plug while pulling the power
cable out of the mains socket.

3. Do not reconnect a defective device to the mains.

Overheating protection

The device is provided with a thermal protection circuit which is
activated by overheating of the device and then switches the
device off.
Switch the device off and let it cool down. Investigate the cause
of overheating. Should the problem persist, please contact the
customer service.

Содержание TDP 370 E

Страница 1: ...TRT BA TDP370E TDP750E TC2020 12 001 EN TDP 370 E TDP 750 E EN ORIGINAL INSTRUCTIONS DEEP WELL PUMP...

Страница 2: ...nstructions must be observed You can download the current version of the instructions and the EU declaration of conformity via the following link TDP 370 E https hub trotec com id 44444 TDP 750 E http...

Страница 3: ...ld onto the mains plug while pulling the power cable out of the mains socket Protect the power supply cable against heat oil and sharp edges Make sure that the power supply cable is not crushed kinked...

Страница 4: ...he device must not be used at freezing temperatures Any unauthorised modifications alterations or structural changes to the device are forbidden Personnel qualifications People who use this device mus...

Страница 5: ...y work on the device remove the mains plug from the mains socket Hold onto the mains plug while pulling the power cable out of the mains socket Warning Dangers can occur at the device when it is used...

Страница 6: ...mains plug while pulling the power cable out of the mains socket Do not use the power cable to drag the device Do not carry the device by holding it at the power cable or hose Storage When the device...

Страница 7: ...with an increasing height of the pressure line Note If you want to connect a flexible hose as pressure line do not use a suction hose or a non pressure resistant hose Use pressure resistant hoses only...

Страница 8: ...falling into the shaft or drill hole Position the device in a way that the shaft or drill hole opening is closed before during and after operation to prevent persons or animals from falling in Note A...

Страница 9: ...y means of the cord or rope 3 Disconnect the pressure line 4 Clean the device according to the Maintenance chapter 5 Store the device according to the Storage chapter Available accessories Warning Onl...

Страница 10: ...ad paired with a small hose diameter can cause a reduction of the conveying capacity Check whether the hose line is kinked or blocked Remove kinks and or blockages Note Wait for at least 3 minutes aft...

Страница 11: ...1 Max power input 700 W 1000 W Max pump capacity 370 W 750 W Protection type of the pump IPX8 IPX8 Protection class I I Connection type CEE 7 7 CEE 7 7 Cable length of the pump 23 m 23 m Min drill ho...

Страница 12: ...p well pump TDP 370 E TDP 750 E Schematic representation TDP 370 E 20 m max max 35 40 m max 0 5 m min TDP 750 E 20 m max max 35 50 m max 0 5 m min Performance chart delivery head flow rate TDP 370 E T...

Страница 13: ...EN 13 deep well pump TDP 370 E TDP 750 E Wiring diagram TDP 370 E TDP 750 E...

Страница 14: ...14 EN deep well pump TDP 370 E TDP 750 E Exploded assembly drawing...

Страница 15: ...ble presser 1 22 Screw 2 48 Cable shield 1 23 Diffuser 4 49 Brass washer 1 24 Impeller 4 50 Cable shield 1 25 Rotor 1 51 Cable short shield 1 26 Bearing 1 52 Electric cable 1 Disposal The icon with th...

Страница 16: ...eep well pump Year of manufacture as of 2020 Relevant EU directives 2011 65 EU 1 July 2011 2014 30 EU 29 March 2014 2014 35 EU 8 September 2017 Applied harmonised standards EN 55014 1 2006 EN 55014 1...

Страница 17: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Отзывы: