The device is running, but not pumping any water:
•
Check whether the dirt strainer (
4
) is clogged. Remove any
obstructions.
•
Check whether the water level is too low or the device is
not completely submerged. If necessary, submerge the
device deeper into the water.
•
Check whether the used hose diameter is too small.
•
Check whether the hose line is kinked or blocked. Remove
kinks and / or blockages.
The device switches off after a brief runtime:
•
Check the water for dirt. If the water is too dirty, the device
will become hot and the thermal protection circuit will
switch the device off.
•
Check whether the water temperature is too high. The
device might have overheated due to a too high water
temperature and the thermal protection circuit is activated.
•
Check the power connection.
•
Check the power cable and mains plug for damage.
•
Check the on-site fusing.
Insufficient or decreasing conveying capacity:
•
Check whether the dirt strainer (
4
) is clogged. Remove any
obstructions.
•
Check the hose diameter and the delivery head. An
excessive delivery head paired with a small hose diameter
can cause a reduction of the conveying capacity.
•
Check whether the hose line is kinked or blocked. Remove
kinks and / or blockages.
Note
Wait for at least 3 minutes after maintenance and
repair work. Only then switch the device back on.
Your device still does not operate correctly after these
checks?
Please contact the customer service. If necessary, bring the
device to an authorized specialist electrical company or to
Trotec for repair.
Maintenance
Activities required before starting maintenance
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
•
Switch the device off.
•
Hold onto the mains plug while pulling the power cable out
of the mains socket.
Notes on maintenance
Inside the device, there are no parts that need to be maintained
or lubricated by the user.
Safety signs and labels on the device
Check the safety signs and labels attached to the device at
regular intervals. Replace illegible safety signs!
Cleaning
•
Clean the device with a soft, damp and lint-free cloth.
Protect electrical components from moisture. Do not use
any aggressive cleaning agents such as cleaning sprays,
solvents, alcohol-based or abrasive cleaners to dampen
the cloth.
•
Rinse the inside of the device with clear, lukewarm water.
Содержание TDP 370 E
Страница 1: ...TRT BA TDP370E TDP750E TC2020 12 001 EN TDP 370 E TDP 750 E EN ORIGINAL INSTRUCTIONS DEEP WELL PUMP...
Страница 13: ...EN 13 deep well pump TDP 370 E TDP 750 E Wiring diagram TDP 370 E TDP 750 E...
Страница 14: ...14 EN deep well pump TDP 370 E TDP 750 E Exploded assembly drawing...
Страница 17: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...