EN
7
spot cooling air conditioning unit PT 5300 SP
Transport and storage
Note
If you store or transport the device improperly, the
device may be damaged.
Note the information regarding transport and storage of
the device.
Transport
Please note that additional transport regulations might apply to
devices containing flammable refrigerants. The equipment's
arrangement and the maximum number of components to be
transported together can be gathered from the applicable
transport regulations.
To make the device easier to transport, it is fitted with wheels.
To make the device easier to transport, it is fitted with a carry
handle.
Before
transporting the device, observe the following:
•
Switch the device off.
•
Hold onto the mains plug while pulling the power cable out
of the mains socket.
•
Drain the remaining condensate from the device.
•
Do not use the power cable to drag the device.
•
Only wheel the device on a level and smooth surface.
While
transporting the device, observe the following:
•
Only transport the device in an upright position.
After
transporting the device, proceed as follows:
•
Set up the device in an upright position after transport.
•
Apply and lock the brakes at the wheels again.
Storage
Before
storing the device, proceed as follows:
•
Clean the condensation tank and/or the condensation drain
hose if necessary (see chapter Maintenance).
•
Drain the remaining condensate from the device.
•
Hold onto the mains plug while pulling the power cable out
of the mains socket.
When the device is not being used, observe the following
storage conditions:
•
Only store the device in a room measuring more than
15 m
2
.
•
Only position the device in rooms where there is no source
of ignition (e.g. open flames, an active gas appliance or an
electric heater).
•
Store the device in a dry location and protected from frost
and heat.
•
Store the device in an upright position where it is protected
from dust and direct sunlight.
•
If required, use a cover to protect the device from invasive
dust.
•
Place no further devices or objects on top of the device to
prevent it from being damaged.
Assembly and start-up
Scope of delivery
•
1 x Device
•
3 x Cold air duct
•
3 x Flue pipe
•
1 x Air filter
•
1 x Condensation tank
•
1 x Manual
Unpacking the device
1. Open the cardboard box and take the device out.
2. Completely remove the packaging.
3. Fully unwind the power cable. Make sure that the power
cable is not damaged and that you do not damage it during
unwinding.
Start-up
When positioning the device, observe the minimum distance
from walls or other objects as described in the Technical data
chapter.
A
B
C
C
D
•
Only position the device in rooms where potentially leaking
refrigerant cannot accumulate.
•
Only position the device in rooms where there is no source
of ignition (e.g. open flames, an active gas appliance or an
electric heater).