spot cooling air conditioning unit PT 5300 SP
Setting the timer
The timer can be programmed in increments of 0.5 hours (0.5 h
to 10 h) and in increments of 1 hour (10 h to 24 h).
The function can be set in all operating modes.
The timer has two modes of operation:
•
automatic switch-on upon expiry of a preset number of
hours
•
automatic switch-off upon expiry of a preset number of
hours
Note
The device must not be left unattended in a freely
accessible room with an activated timer.
Automatic switch-on
ü
The device is switched off.
1. Press the
Timer
button (
19
) to activate the timer.
2. Press the
decrease value
(
14
) or
increase value
button (
13
)
to select the desired number of hours until automatic
switch-on.
ð
The segment display (
12
) continuously indicates the
number of hours until automatic switch-on.
ð
After the predefined time, the device switches itself on.
Notes regarding automatic switch-on:
•
If the device is disconnected from the power supply, all
settings for automatic switch-on are deleted.
•
Manually switching the device on disables the automatic
switch-on function.
•
If you select
0
hours, the timer will be off.
Automatic switch-off
ü
The device is switched on.
1. Press the
Timer
button (
19
) to activate the timer.
2. Press the
decrease value
(
14
) or
increase value
button (
13
)
to select the desired number of hours until automatic
switch-off.
ð
The number of hours until automatic switch-on will be
indicated on the segment display (
12
) for approx.
3 seconds.
ð
After the predefined time, the device switches itself off.
Notes regarding automatic switch-off:
•
If the device is disconnected from the power supply, all
settings for automatic switch-on are deleted.
•
Manually switching the device off disables the automatic
switch-off function.
Connecting the condensation hose
The device can be operated with a condensation hose (
29
).
ü
A suitable condensation hose is provided (diameter 16 mm).
1. Remove the condensation tank from the device.
2. Connect the condensation hose (
29
) to the condensation
connection (
30
) in the interior of the device.
29
30
3. Guide the other hose end to a suitable drain or sufficiently
dimensioned collection container. To ensure that the
condensate can run off, the condensation drain hose must
not be kinked, nor should it have to overcome an uphill
incline towards the drain.