16
EN
local air conditioner PAC 3500 X
4. Reinsert the air filter into the device.
Condensate discharge (manual draining)
In
cooling
and
dehumidification
mode condensate is formed,
which is mostly discharged via the exhaust air.
The remaining condensate is collected in a container within the
housing. The condensate ought to be drained regularly.
If too much condensate accumulates, the device switches off
and the
water filling level
LED (15) is illuminated.
1. Carefully transport or wheel the device to a suitable
location for discharging the condensate (e.g. a drain) or
position a suitable collection container under the
condensate outlet.
2. Remove sealing cap and rubber stopper from the
condensate outlet.
3. Drain the condensate.
4. Reinsert the rubber stopper in the condensate outlet and
reattach the sealing cap. Ensure the tight fit of the rubber
stopper, for otherwise there might be uncontrolled water
leakage.
ð
The
water filling level
LED (15) will go out as soon as
the condensate has been drained.
Activities required after maintenance
If you want to continue using the device:
•
Leave the device to rest for 12 to 24 hours, so the
refrigerant can accumulate within the compressor. Wait
12 to 24 hours before switching the device back on! Acting
contrary might lead to compressor damage and a
malfunctioning device. If so, any warranty claims will be
voided.
•
Reconnect the device to the mains.
If you do not intend to use the device for a considerable time:
•
Store the device according to the Storage chapter.