![Trotec 8017 Скачать руководство пользователя страница 30](http://html1.mh-extra.com/html/trotec/8017/8017_operation-manual_1172300030.webp)
8017 Trotec Speedy
300 fiber
OPERATION
28/07/2015
Trotec Produktions- und Vertriebs GmbH
_Linzer Strasse 156, A-4600 Wels, Austria, Technical Support
30 / 54
tel_+43 (0)7242 239-7000, fax_+43 (0)7242 239-7380, mailto:
2
POSITIONING KEYS X/Y
Use the positioning keys to manually move the lens holder into the
indicated directions.
When you press two keys simultaneously, the lens holder moves
diagonally.
When you press the "Shift" key and one of the positioning keys
simultaneously, a movement to the corresponding end position is
performed.
If all panels are closed, the movement is done with the maximum
velocity, if opened, the speed is 1/4
th
of the maximum.
While the Z- axis is in movement (e.g. autofocus), no cursor moves in X
and Y axis are performed.
The status display (9) of the device is located in the center of the key
pad.
3
PAUSE
Used to stop the current working process (key lights up). As soon as
the last processing command is finished, the motion system stops.
If this key is pressed a second time, the key illumination goes off, the
interrupted working process is continued.
4
STANDBY
Switches the device into Standby mode (Laser ready)
– key lights up.
By pressing the key again the device is switched back to Ready mode.
If the Standby button is pressed while the Z- axis is in an automatic
move (e.g. autofocus), the Standby mode is entered after finishing the
Z- axis- move (Z- axis move can be stopped by pressing any of the Z-
axis keys).
5
EXHAUST
Used to manually switch the exhaust system on and off.
The key illumination shows the status of the exhaust system. When the
key is illuminated, the exhaust system is switched on.
After completing the process, the exhaust system can only be switched
off after some seconds (follow-up time).