6
“SHIFT” (TEST) key for 2
nd
function key level
For additional Operations. When this key is pressed together with the
following keys, the functions indicated are activated:
- Exhaust (5):
Air assist on/off
- Pause (3)
Stops the job program immediately
- Positioning keys X/Y/Z (2):
These keys drive the laser head to the end position
- Repeat
Tests the laser source for proper function (acoustic signal sounds
simultaneously)
7
START (REPEAT)
By pressing “Start (Repeat)”, the jobs which are currently positioned on
the selected plate in the Trotec JobControl are started.
If the jobs have been processed before, they will be reset automatically.
8
STATUS INDICATOR LASER BEAM
Indicates, that a laser beam is currently being emitted.
9
STATUS DISPLAY
Indicates the current status of the device.
green, flashing slowly (0.5 Hz)
9
Machine is ready
green, flashing fast (2 Hz)
9
Cover has been opened
green permanent light /
Pause mode
9
Data available in the machine
red permanent light
8
Laser beam is being emitted
green/red flashing alternately
8+9
Cover open during switch-on process,
simultaneously acoustic signal -
no referencing