background image

Thermostatic electric shower

7

ImpoRtaNt:

 

If installing onto a tiled wall 

always mount the unit on the surface of the 
tiles. never tile up to the unit.

Refer to 

fig.6

 for correct siting of the shower.

Position the unit where it will NOT

 

be in direct 

contact with water from the showerhead. 
Position the shower unit vertically.
Allow enough room between the ceiling and the 
shower to access the cover top screws.

Note:

 Water regulations require the showerhead 

be

 ‘constrained by a fixed or sliding attachment 

so that it can only discharge water at a point 
not less than 25 mm above the spill-over level 
of the relevant bath, shower tray or other fixed 
appliance’

. The use of the supplied soap dish will 

in most cases meet this requirement, but if the 
showerhead can be placed within a bath, basin 
or shower tray, then a double check valve, or 
similar, must be fitted in the supply pipework to 
prevent back-flow.

ImpoRtaNt:

 

Using a suitable sealant, always 

seal around the incoming pipework to 
prevent water entering the wall.

Liquid Crystal Display

This shower unit has a LCD which has an 
optimum viewing angle that is slightly below eye 
level. Therefore position the unit so the display 
is at nose level. For multiple users of varying 
heights, an optimum shower height must be 
arrived at.

Pressure relief safety device

A pressure relief device (PRD) is designed into 
the shower unit which complies with European 
standards. The PRD provides a level of appliance 
protection should an excessive build up of 
pressure occur within the shower.
DO NOT operate the shower with a damaged or 
kinked shower hose, or a blocked showerhead 
which can cause the PRD to operate.

Outline of bath

or shower tray

Mains cold water

supply - bottom,

top and back

Riser rail can

be mounted either

side of shower

25 mm minimum

Soap dish

retaining

ring

Spillover

level

Height of 

showerhead

and

shower 

to suit

user's

requirement

Shower unit

must not

be within

an area

1 metre

from base

Fig.6

  

Diagrammatic view (not to scale)

ImpoRtaNt:

 

the unit must be mounted 

on a flat surface which covers the full width 
and length of the backplate, otherwise 
difficulty may arise when fitting the cover 
and subsequent operation of the unit may 
be impaired.

WaRNING!

the shower must not be positioned 

where it will be subjected to freezing 

conditions.

SITING OF THE SHOWER

SITING OF THE SHOWER

Содержание Topaz T100si

Страница 1: ...INSTALLERS PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER 2180360p November 2011 Topaz T100si thermostatic control electric shower Installation and operating instructions...

Страница 2: ...he cover 13 Operating the shower 14 Operating functions 17 Cleaning 19 Instructions for installers and service engineers only 20 21 Spare parts 22 23 Fault finding 24 25 Guarantee service policy etc r...

Страница 3: ...unit will result in higher temperatures and could also cause the PRD Pressure Relief Device in the unit to operate 1 9 This product is not suitable for mounting into steam rooms or steam cubicles 2 P...

Страница 4: ...ied person and in the sequence of this instruction book Care taken during the installation will provide a long trouble free life from your shower SPECIFICATIONS Electrical Nominal power Nominal power...

Страница 5: ...Earth connection 10 PRD 11 Solenoid valve 12 Trimplate 13 Thermostatic valve 14 Scale trap 15 Pressure switch 16 Shower outlet 17 Guide pockets Inside cover fig 2 18 Control printed circuit board 19 S...

Страница 6: ...re fuse way which will take the fuse or Miniature Circuit Breaker MCB necessary for the shower Fig 4 4 1 If your consumer unit has a rating below 80A or if there is no spare fuse way then the installa...

Страница 7: ...8 The current carrying capacity of the cable must be at least that of the shower circuit protection see Table B 8 1 To obtain full advantage of the power provided by the shower use the shortest cable...

Страница 8: ...ult a competent plumber Under site conditions where the power supply is below 220 volts and the mains water pressure is above 5 bar it is recommended to fit a pressure reducing valve set at 3 5 bar A...

Страница 9: ...ich has an optimum viewing angle that is slightly below eye level Therefore position the unit so the display is at nose level For multiple users of varying heights an optimum shower height must be arr...

Страница 10: ...shower is positioned over a bath or shower tray because if the PRD operates then water will eject from the bottom of the unit Should this happen turn off the electricity and water supplies to the show...

Страница 11: ...from the rear or bottom the centre of the inlet valve to the wall surface is 21 mm fig 10 Note If entry is from the rear the nut of the compression fitting will be partially behind the surface of the...

Страница 12: ...ff the water supply either at the mains stopvalve or the isolating stopvalve Connect the mains water supply to the inlet fig 12 of the shower via 15 mm copper stainless steel or plastic pipe using a 1...

Страница 13: ...routing through conduit or in trunking or by embedding in the wall in accordance with current IEE regulations The use of connections within the unit or other points in the shower circuit to supply pow...

Страница 14: ...o position so that the control spindle locates correctly the flats only allow the spindle and knob only fit one way Should any difficulty arise recheck the points above While applying slight pressure...

Страница 15: ...sure the pipe and cable entering the unit do not prevent the cover locating correctly to the backplate d Make sure the valve spindle has the flat and keyway slot uppermost 12 o clock position e Make s...

Страница 16: ...lay shows FUL fig 20 indicating full power is being used After a few seconds two up arrows start flashing indicating the unit is working towards its preset showering temperature fig 21 This is achieve...

Страница 17: ...the same temperature as before Note If the setting was high at full power then it will not be possible to obtain the same temperature on economy power The shower will try to provide the highest tempe...

Страница 18: ...fig 27 position all inner segments full that corresponds to the control position To decrease the shower temperature Turn the temperature control anti clockwise the current temperature display is repla...

Страница 19: ...ean the showerhead or not The shower will then reset automatically for a further preset number of shower operations before flashing the reminder again Low pressure When the display backlight turns red...

Страница 20: ...e of the fault and replace the safety device once the unit has been repaired Changing the fascia This shower unit has the facility for the coloured fascia to be simply changed for another colour of yo...

Страница 21: ...y affect the product surface finish and invalidate your guarantee It is important to keep the showerhead clean to maintain the performance of the shower The hardness of the water will determine the fr...

Страница 22: ...son Switch off the electricity supply at the mains Remove the cover The inlet filter is situated in the solenoid inlet fig 54 and can be removed to clean To gain access to the filter will require the...

Страница 23: ...omplete with O rings Be aware of water discharging as the heater can exhausts Clean out the trap and remove all sediment Flush the can through by leaving the cap off and switching on the power at the...

Страница 24: ...or 9 5kW 22010310 Restrictor 10 5kW 22010410 5 Solenoid valve assembly and O ring 83307110 6 Pressure Relief Device 82800450 7 Trimplate 7052989 8 Can brace 7053008 9 Thermostatic valve and O rings 4...

Страница 25: ...set 2 x earth 1 x solenoid wires 83307150 Power PCB carrier 7052991 Rubber microswitch cover 7063046 Inlet filter 7053009 16 Coloured fascias Seaspray TSTZFSEA Aqua TSTZFAQU Azure TSTZFAZU Lilac TSTZF...

Страница 26: ...Unit malfunction 2 2 1 Contact Customer Service 3 Water too hot 3 1 Temperature control incorrect setting 3 1 1 Turn anti clockwise 3 2 Unit malfunction 3 2 1 Contact Customer Service 4 Unstable show...

Страница 27: ...or flashing 6 4 Blocked connecting tube to pressure switch 6 4 1 Make sure the tube from solenoid valve to pressure switch is not kinked or blocked 7 Water continues to flow when unit is isolated at i...

Страница 28: ...umber and power rating of the product together with the date of purchase and where applicable details of the particular fault 2 If required the Customer Service Advisor will arrange for a qualified en...

Страница 29: ...Showers Power Showers Smart Showers Shower Towers From Top Shower Brands Mira Showers Aqualisa Showers Triton Showers Gainsborough Showers Shower Pumps can upgrade your showering experience even more...

Отзывы: