background image

Thermostatic electric shower

1

Products manufactured by Triton are safe and without risk provided they are installed, used and 

maintained in good working order in accordance with our instructions and recommendations.

WARNING:

 

DO NOT

 operate shower if frozen, or suspected of being frozen. It must thaw out 

before using.

DO NOT

 operate the unit if the showerhead or spray hose becomes damaged.

DO NOT

 restrict flow out of shower by placing showerhead in direct contact with your body.

DO NOT

 operate the shower if water ceases to flow during use or if water has entered inside 

the unit because of an incorrectly fitted cover.

WARNING:

 If restarting the shower immediately after stopping, be aware that a slug of 

hot water will be expelled for the first few seconds.

PLEASE READ THIS IMPORTANT SAFETY INFORMATION

GENERAL

1.1 

Isolate the electrical and water supplies before 

removing the cover.

1.2 

Read all of these instructions and retain them 

for later use.

1.3 

DO NOT

 take risks with plumbing or electrical 

equipment.

1.4 

Isolate electrical and water supplies before 

proceeding with the installation.

1.5 

The unit must be mounted onto the finished 

wall surface (on top of the tiles). 

DO NOT

 tile 

up to or seal around 

ANY PART

 of the unit 

using silicone sealer after fixing to the wall. 

Special care must be taken 

NOT TO BLOCK 

OR SEAL ANY PRD VENTS ON THE UNIT

.

1.6 

Contact Customer Service 

(see back page)

, if 

any of the following occur:

a) 

If it is intended to operate the shower at 

pressures above the maximum or below the 

minimum stated.

b) 

If the unit shows a distinct change in 

performance.

c) 

If the shower is frozen.

1.7 

If it is intended to operate the shower in areas 

of hard water (above 200 ppm temporary 

hardness), a scale inhibitor may have to be 

fitted. For advice on the Scale Inhibitor, 

contact Customer Service.

1.8 

The showerhead must be cleaned regularly 

with descalent to remove scale and debris, 

otherwise restrictions to the flow on the outlet 

of the unit will result in higher temperatures 

and could also cause the (PRD) Pressure Relief 

Device in the unit to operate.

1.9 

This product is not suitable for mounting into 

steam rooms or steam cubicles.

2 PLUMBING

2.1 

The plumbing installation must comply with 

Water Regulations, Building Regulations or any 

particular regulations as specified by Local 

Water Company or Water Undertakers and 

should be in accordance with BS 6700.

2.2 

The supply pipe must be flushed to clear debris 

before connecting to the shower unit.

2.3 

DO NOT

 solder pipes or fittings within 300mm 

of the shower unit, as heat can transfer along 

the pipework and damage components.

2.4 

DO NOT

 fit any form of outlet flow control as 

the outlet acts as a vent for the heater can.

2.5 

DO NOT

 use excessive force when making 

connections to the flexible hose or 

showerhead, finger tight is sufficient.

2.6 

All plumbing connections must be completed 

before making the electrical connections.

3 ELECTRICAL

3.1 

The installation must comply with BS 7671 

‘Requirements for electrical installations’ (IEE 

wiring regulations), building regulations or any 

particular regulations as specified by the local 

Electrical Supply Company.

3.2 

This appliance 

MUST 

be earthed.

3.3 

In accordance with ‘The Plugs and Sockets etc. 

(Safety) Regulations 1994’, this appliance is 

intended to be permanently connected to the 

fixed wiring of the electrical mains system.

3.4 

Make sure all electrical connections are tight to 

prevent overheating.

3.5 

A 30mA residual current device (RCD) 

MUST 

be installed in all UK electric and pumped 

shower circuits. This may be part of the 

consumer unit or a separate unit.

3.6 

Switch off immediately at isolating switch if 

water ceases to flow during use.

3.7 

Other electrical equipment i.e. extractor fans, 

pumps must not be connected to the circuits 

within the unit.

3.8 

Switch off at isolating switch when not in use. 

This is a safety procedure recommended with 

all electrical appliances.

3.9 

As with all electrical appliances it is 

recommended to have the shower and 

installation checked at least every two years by 

a competent electrician to ensure there is no 

deterioration due to age and usage.

Содержание Topaz T100si

Страница 1: ...INSTALLERS PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER 2180360p November 2011 Topaz T100si thermostatic control electric shower Installation and operating instructions...

Страница 2: ...he cover 13 Operating the shower 14 Operating functions 17 Cleaning 19 Instructions for installers and service engineers only 20 21 Spare parts 22 23 Fault finding 24 25 Guarantee service policy etc r...

Страница 3: ...unit will result in higher temperatures and could also cause the PRD Pressure Relief Device in the unit to operate 1 9 This product is not suitable for mounting into steam rooms or steam cubicles 2 P...

Страница 4: ...ied person and in the sequence of this instruction book Care taken during the installation will provide a long trouble free life from your shower SPECIFICATIONS Electrical Nominal power Nominal power...

Страница 5: ...Earth connection 10 PRD 11 Solenoid valve 12 Trimplate 13 Thermostatic valve 14 Scale trap 15 Pressure switch 16 Shower outlet 17 Guide pockets Inside cover fig 2 18 Control printed circuit board 19 S...

Страница 6: ...re fuse way which will take the fuse or Miniature Circuit Breaker MCB necessary for the shower Fig 4 4 1 If your consumer unit has a rating below 80A or if there is no spare fuse way then the installa...

Страница 7: ...8 The current carrying capacity of the cable must be at least that of the shower circuit protection see Table B 8 1 To obtain full advantage of the power provided by the shower use the shortest cable...

Страница 8: ...ult a competent plumber Under site conditions where the power supply is below 220 volts and the mains water pressure is above 5 bar it is recommended to fit a pressure reducing valve set at 3 5 bar A...

Страница 9: ...ich has an optimum viewing angle that is slightly below eye level Therefore position the unit so the display is at nose level For multiple users of varying heights an optimum shower height must be arr...

Страница 10: ...shower is positioned over a bath or shower tray because if the PRD operates then water will eject from the bottom of the unit Should this happen turn off the electricity and water supplies to the show...

Страница 11: ...from the rear or bottom the centre of the inlet valve to the wall surface is 21 mm fig 10 Note If entry is from the rear the nut of the compression fitting will be partially behind the surface of the...

Страница 12: ...ff the water supply either at the mains stopvalve or the isolating stopvalve Connect the mains water supply to the inlet fig 12 of the shower via 15 mm copper stainless steel or plastic pipe using a 1...

Страница 13: ...routing through conduit or in trunking or by embedding in the wall in accordance with current IEE regulations The use of connections within the unit or other points in the shower circuit to supply pow...

Страница 14: ...o position so that the control spindle locates correctly the flats only allow the spindle and knob only fit one way Should any difficulty arise recheck the points above While applying slight pressure...

Страница 15: ...sure the pipe and cable entering the unit do not prevent the cover locating correctly to the backplate d Make sure the valve spindle has the flat and keyway slot uppermost 12 o clock position e Make s...

Страница 16: ...lay shows FUL fig 20 indicating full power is being used After a few seconds two up arrows start flashing indicating the unit is working towards its preset showering temperature fig 21 This is achieve...

Страница 17: ...the same temperature as before Note If the setting was high at full power then it will not be possible to obtain the same temperature on economy power The shower will try to provide the highest tempe...

Страница 18: ...fig 27 position all inner segments full that corresponds to the control position To decrease the shower temperature Turn the temperature control anti clockwise the current temperature display is repla...

Страница 19: ...ean the showerhead or not The shower will then reset automatically for a further preset number of shower operations before flashing the reminder again Low pressure When the display backlight turns red...

Страница 20: ...e of the fault and replace the safety device once the unit has been repaired Changing the fascia This shower unit has the facility for the coloured fascia to be simply changed for another colour of yo...

Страница 21: ...y affect the product surface finish and invalidate your guarantee It is important to keep the showerhead clean to maintain the performance of the shower The hardness of the water will determine the fr...

Страница 22: ...son Switch off the electricity supply at the mains Remove the cover The inlet filter is situated in the solenoid inlet fig 54 and can be removed to clean To gain access to the filter will require the...

Страница 23: ...omplete with O rings Be aware of water discharging as the heater can exhausts Clean out the trap and remove all sediment Flush the can through by leaving the cap off and switching on the power at the...

Страница 24: ...or 9 5kW 22010310 Restrictor 10 5kW 22010410 5 Solenoid valve assembly and O ring 83307110 6 Pressure Relief Device 82800450 7 Trimplate 7052989 8 Can brace 7053008 9 Thermostatic valve and O rings 4...

Страница 25: ...set 2 x earth 1 x solenoid wires 83307150 Power PCB carrier 7052991 Rubber microswitch cover 7063046 Inlet filter 7053009 16 Coloured fascias Seaspray TSTZFSEA Aqua TSTZFAQU Azure TSTZFAZU Lilac TSTZF...

Страница 26: ...Unit malfunction 2 2 1 Contact Customer Service 3 Water too hot 3 1 Temperature control incorrect setting 3 1 1 Turn anti clockwise 3 2 Unit malfunction 3 2 1 Contact Customer Service 4 Unstable show...

Страница 27: ...or flashing 6 4 Blocked connecting tube to pressure switch 6 4 1 Make sure the tube from solenoid valve to pressure switch is not kinked or blocked 7 Water continues to flow when unit is isolated at i...

Страница 28: ...umber and power rating of the product together with the date of purchase and where applicable details of the particular fault 2 If required the Customer Service Advisor will arrange for a qualified en...

Страница 29: ...Showers Power Showers Smart Showers Shower Towers From Top Shower Brands Mira Showers Aqualisa Showers Triton Showers Gainsborough Showers Shower Pumps can upgrade your showering experience even more...