T300si electric shower
Y-006-A
ELECTROMAGNETIC COMPATIBILITY
This product is intended for domestic use.
This product may temporarily be affected by
electromagnetic disturbance near to the installation
that could cause temporary operation of the low
pressure indicator together with switching to the cold
power selection. If problems persist, contact Triton
Customer Service (see rear page).
The following points will help you understand
how the shower operates:
a.
The electric heating elements operate at a
constant rate at your chosen power setting. It is
the rate of the water passing through the heater
unit which determines the shower temperature
at a given setting. (The slower the flow the
hotter the water becomes, and the faster the
flow the cooler the water).
b.
During the winter the cold water supply
will be cooler than in the summer months.
Therefore, the temperature of the water will
vary from season to season on any one setting
of the control buttons, e.g. if you have chosen
'Economy' power for your preferred shower
temperature in the summer, you will have
to select the 'High' setting and adjust the
temperature control during the winter months.
c.
The stabiliser valve minimises variations in
shower temperature during mains water pressure
changes. If changes in shower temperature are
experienced during normal use, it will most
likely be caused by the water pressure falling
near to or below the minimum level. The drop
in pressure may be due to water being drawn
off at other points in the house while the
shower is in use. If pressure drops appreciably
below the minimum, the heating elements will
automatically cut out.
If ever the water becomes too hot and you
cannot obtain cooler water, first check the
showerhead has not become blocked.
This book contains all the necessary fitting and
operating instructions for your Triton T300si
electric shower — please read them carefully.
The shower installation must be carried out by a
suitably qualified person and in the sequence of
this instruction book.
Care taken during the installation will ensure a
long, trouble-free life from your shower.
Specifications
SPECIFICATIONS
Electrical
Nominal power
Nominal power
rating at 240V
rating at 230V
8.5kW – (40A MCB rating) 7.8kW – (40A MCB rating)
9.5kW – (40A MCB rating) 8.7kW – (40A MCB rating)
10.5kW – (45A MCB rating) 9.6kW – (40A MCB rating)
Water
Inlet connection – 15 mm diameter.
Outlet connection – ½” BSP male thread.
Entry Points
Water – bottom or back.
Cable – top or back.
Materials
Backplate, cover, controls, showerhead – ABS.
Sprayplate – Acetal.
Elements – Minerally insulated corrosion resistant
metal sheathing.
Dimensions (in mm)
control panel remote pack
Height
235
338
Width
180
208
Depth
40
98
Standards and Approvals
Splashproof rating IPX4.
Complies with the requirements of current British
and European safety standards for household
and similar electrical appliances.
Complies with requirements of the British
Electrotechnical Approvals Board (BEAB).
Meets with Compliance with European
Community Directives (CE).
Introduction
INTRODUCTION
Advice to users
ADVICE TO USERS
I-003-A
IMPORTANT:
When first installed (or following
replacement of the PRD), the unit will be empty. It
is essential the heater assembly contains water
before the elements are switched on. As this unit
has electronic control, it is vital that the
commissioning procedure is followed. Failure to
carry out this operation will result in damage to
the unit and will invalidate the guarantee.
Y-003-A
Replacement parts can be ordered from Customer
Service. See
‘spare parts’
for details and part numbers.
Содержание T300si
Страница 31: ...T300si electric shower 29...