background image

T300si electric shower

Y-006-A

ELECTROMAGNETIC COMPATIBILITY

This product is intended for domestic use.

This  product  may  temporarily  be  affected  by 
electromagnetic  disturbance  near  to  the  installation 
that  could  cause  temporary  operation  of  the  low 
pressure indicator together with switching to the cold 
power  selection.  If  problems  persist,  contact  Triton 
Customer Service (see rear page).

The following points will help you understand 
how the shower operates:

a.

 

The electric heating elements operate at a 

constant rate at your chosen power setting. It is 
the rate of the water passing through the heater 
unit which determines the shower temperature 
at a given setting. (The slower the flow the 
hotter the water becomes, and the faster the 
flow the cooler the water).

b.

  During the winter the cold water supply 

will be cooler than in the summer months. 
Therefore, the temperature of the water will 
vary from season to season on any one setting 
of the control buttons, e.g. if you have chosen 
'Economy' power for your preferred shower 
temperature in the summer, you will have 
to select the 'High' setting and adjust the 
temperature control during the winter months.

c.

  The stabiliser valve minimises variations in 

shower temperature during mains water pressure 
changes. If changes in shower temperature are 
experienced during normal use, it will most 
likely be caused by the water pressure falling 
near to or below the minimum level. The drop 
in pressure may be due to water being drawn 
off at other points in the house while the 
shower is in use. If pressure drops appreciably 
below the minimum, the heating elements will 
automatically cut out. 

If ever the water becomes too hot and you 
cannot obtain cooler water, first check the 
showerhead has not become blocked.

This book contains all the necessary fitting and 
operating instructions for your Triton T300si 
electric shower — please read them carefully.
The shower installation must be carried out by a 
suitably qualified person and in the sequence of 
this instruction book.
Care taken during the installation will ensure a 
long, trouble-free life from your shower.

Specifications

SPECIFICATIONS

Electrical

 

Nominal power 

Nominal power 

rating at 240V 

rating at 230V 

8.5kW – (40A MCB rating)  7.8kW – (40A MCB rating) 
9.5kW – (40A MCB rating)  8.7kW – (40A MCB rating) 
10.5kW – (45A MCB rating)  9.6kW – (40A MCB rating)

Water

 

Inlet connection – 15 mm diameter. 

Outlet connection – ½” BSP male thread.

Entry Points

 

Water – bottom or back. 

Cable – top or back.

Materials

 

Backplate, cover, controls, showerhead – ABS. 

Sprayplate – Acetal. 

Elements – Minerally insulated corrosion resistant 

metal sheathing.

Dimensions (in mm)

 

 

control panel  remote pack 

Height 

235 

338 

Width 

180 

208 

Depth 

40 

98

Standards and Approvals 

Splashproof rating IPX4.
Complies with the requirements of current British 
and European safety standards for household 
and similar electrical appliances.
Complies with requirements of the British 
Electrotechnical Approvals Board (BEAB).
Meets with Compliance with European 
Community Directives (CE).

Introduction

INTRODUCTION

Advice to users

ADVICE TO USERS

I-003-A

IMPORTANT:

  When  first  installed  (or  following 

replacement of the PRD), the unit will be empty. It 

is  essential  the  heater  assembly  contains  water 

before the elements are switched on. As this unit 

has  electronic  control,  it  is  vital  that  the 

commissioning  procedure  is  followed.  Failure  to 

carry  out  this  operation  will  result  in  damage  to 

the unit and will invalidate the guarantee.

Y-003-A

Replacement parts can be ordered from Customer 
Service. See 

‘spare parts’

 for details and part numbers.

Содержание T300si

Страница 1: ...Installation and operating instructions T300si electric shower 2180280J May 2008 Installers please note these instructions are to be left with the user...

Страница 2: ...t 17 Fitting the control panel 18 Fitting the remote pack cover 18 Commissioning 19 Operating the shower 21 Operating functions 23 Cleaning 24 Instructions for installers and service engineers only 25...

Страница 3: ...nd could also cause the Pressure Relief Device in the unit to operate This product is not suitable for mounting into steam rooms or steam cubicles PLUMBING The plumbing installation must comply with W...

Страница 4: ...cannot obtain cooler water first check the showerhead has not become blocked This book contains all the necessary fitting and operating instructions for your Triton T300si electric shower please read...

Страница 5: ...9 Solenoid valve 10 Guide pockets 11 Can and element assembly 12 Thermal safety cut out main 13 Earth connection 14 Control cable clamp 15 Thermal cut out outlet 16 Outlet pipe 17 Transformer 18 Conn...

Страница 6: ...ircuits This may be part of the consumer unit or a separate unit 6 A 45 amp double pole isolating switch with a minimum contact gap of 3 mm in both E 002 A 230 240V ac supply If you are installing a s...

Страница 7: ...and cable size there is a maximum permissible circuit length 9 The shower circuit should be separated from other circuits by at least twice the diameter of the cable or conduit 9 1 The current rating...

Страница 8: ...m ow rate of eleven litres per minute For all units the maximum static pressure must be no greater than 1000kPa 10 bar If in any doubt the pressure should be checked Note If the stated ow rate is not...

Страница 9: ...ouble check valve or a similar device must be fitted in the supply pipework to prevent back flow Pressure relief safety device A pressure relief device PRD is designed into the shower unit which compl...

Страница 10: ...mark the position of the 15 mm hole Drill and channel a route as required Place and position the control cable between the remote pack and control panel Make sure there is enough slack cable at the re...

Страница 11: ...mote pack is installed in a loft area the following requirements must be met for future servicing purposes a There must be no risk of the remote pack heated water pipe or PRD tube becoming frozen b Th...

Страница 12: ...wall Entry positions for the mains water are from the bottom or from the rear Cable entry is via the top or rear Note Deviations from the designated entry points will invalidate product approvals If...

Страница 13: ...of the remote pack flush out the pipework to remove all swarf and system debris This do this connect a hose to the pipework and turn on the mains water supply long enough to clear the debris to waste...

Страница 14: ...from the remote pack Any surplus can be cut off as required Note The water outlet does not need to be vertically above or below the control panel If required the outlet adaptor and control panel can...

Страница 15: ...as they are similar in diameter and length the PRD tube is clear Important Do not bend either the PRD tube or heated water pipe sharply as they will kink and restrict the water flow If a tight bend i...

Страница 16: ...bulkhead and its cover are supplied assembled Separate the two halves by carefully prising apart at the smaller of the two elbow apertures Secure the elbow to the bulkhead body with the three screws s...

Страница 17: ...to the back of the bulkhead Apply PTFE tape to the threaded connector Screw the bulkhead assembly onto the threaded connector until tight to the wall and the two fixing holes are aligned Secure to th...

Страница 18: ...l block screws and check that no cable insulation is trapped under the screws Loose connections can result in cable overheating Note The supply cable earth conductor must be sleeved The outer sheath o...

Страница 19: ...access panel fig 28 to reveal the connector socket Cable entry into the remote pack is through one of the built in cut outs Remove the protective dust covers from both ends of the control cable Once t...

Страница 20: ...e purge pin is located on its two pins the factory set position see fig 34 Locate the tags on the cover into the holes on the backplate and guide into position Secure the cover in position with the th...

Страница 21: ...old and low pressure This flashing sequence lasts about twenty seconds All lights will then go out except the Start Stop surround indicating that power is on to the unit Press the Start Stop button fi...

Страница 22: ...off its two pins and in order to store it for use at a later date replace it on one of the pins Replacing the remote pack cover Locate the tags on the cover into the holes on the backplate and guide i...

Страница 23: ...switch All lights will go out except the Start Stop surround indicating that power is on to the unit The shower is now ready for normal operation To start the shower Press the Start Stop button and im...

Страница 24: ...a different temperature to the same number position on high To decrease the shower temperature Turn the temperature control anti clockwise fig 36 This will increase the flow of water through the showe...

Страница 25: ...in operation Phased shutdown In use when the Start Stop button is pressed power is switched off to the elements Water continues to flow for a few seconds flushing out any remaining hot water This make...

Страница 26: ...once the unit has been repaired W 007 A WARNING DO NOT use abrasive or aggressive cleaning products when cleaning the shower as they may damage the unit Cleaning CLEANING Before cleaning turn off the...

Страница 27: ...id inlet fig 42 To gain access to the filter remove the cover then disconnect and remove the compression fitting Also depending on the incoming pipework arrangements if there is not enough slack in th...

Страница 28: ...Solenoid valve 83304130 10 Outlet pipe assembly 85000090 11 Trimplate 7051754 12 PRD O ring 83301330 13 Remote pack cover 85200030 14 PCB control panel 7072569 15 Control panel assembly white 8740002...

Страница 29: ...er supply mains or tank fed If tank fed replumb to mains water supply or see 4 2 4 If mains fed make sure that the mains stopvalve is fully open and there are no other restrictions in the supply while...

Страница 30: ...nit with showerhead removed Fit pressure reducing valve to inlet and then fit new PRD 4 2 3 4 2 4 4 3 1 4 3 2 4 4 1 5 1 1 6 1 1 6 2 1 6 2 2 7 1 1 7 2 1 7 3 1 7 4 1 required see rating label Reduction...

Страница 31: ...T300si electric shower 29...

Страница 32: ...onshowers co uk Triton Showers Triton Road Nuneaton Warwickshire CV11 4NR Triton is a division of Norcros Group Holdings Limited TRiTon STandaRd GuaRanTee Triton guarantee this product against all mec...

Отзывы: