Replacing the cover
REPLACING THE COVER
Valve
spindle
Fig.15
Fig.16
IMPORTANT:
Before finally fitting the cover,
the following steps must be taken:
a.
Check all plumbing connections are
watertight.
b.
Check terminal block screws are fully
tightened.
c.
Make sure the pipe and cable entering
the unit do not prevent the cover locating
correctly to the backplate.
d.
Make sure the valve spindle has the ‘flat’
and keyway slot uppermost, the 12 o’clock
position
(fig.15).
e.
Make sure the temperature control knob
on the cover is rotated to 12 o’clock, the
knob ‘flat’ inside the cover should be
uppermost
(fig.16)
.
Offer the cover to the unit. Carefully locate
the cover tags into the guide pockets on the
backplate and check the wires are not trapped.
Guide into position so that the control spindle
locates correctly (the ‘flats’ ensure the spindle
and knob will only fit one way). While applying
slight pressure to the front cover, secure in
position with the three retaining screws.
The flexible hose can be left attached to the
shower outlet. Make sure the supplied sealing
washer is fitted.
Once the riser rail kit is installed, the shower is
ready for normal operation.
W-004-A
WARNING!
The outlet of the shower acts as a
vent and MUST NOT be connected to
anything other than the hose and
showerhead supplied.
W-020-A
WARNING!
This appliance is not intended for use
by young children or infirm persons
unless they have been adequately
supervised by a responsible person to
ensure that they can use the appliance
safely.
Young children should be supervised to
ensure that they do not play with the
appliance.