Fault finding
FAULT FINDING
IMPORTANT:
Switch off the electricity at the mains supply and remove the circuit fuse before
attempting any fault finding inside the unit.
Problem/Symptom Cause
Action/Cure
1
Shower inoperable.
2
Water flows when
isolating switch is
switched on.
3
Water too hot.
4
Unstable shower
temperature or flow.
5
Water too cool or
cold.
6
‘
LP’ flashing on
display.
1.1
Interrupted power
supply.
1.2
Unit malfunction.
2.1
Ribbon cable is
not connected.
2.2
Unit malfunction.
3.1
Temperature
control incorrect
setting.
3.2
Unit malfunction.
4.1
Blockages.
4.2
Loose ribbon
cable connection.
4.3
Unit malfunction.
5.1
Temperature
control incorrect
setting.
5.2
Unit malfunction.
5.3
Safety cut-out
operated.
6.1
Water pressure
has dropped below
minimum required.
6.2
Blockage in outlet.
6.3
Loose connection
on PCB.
6.4
Blocked
connecting tube to
pressure switch.
1.1.1
Blown fuse or circuit breaker. Check
supply. Renew or reset fuse or circuit breaker. If it
fails again, consult a qualified electrician.
1.1.2
Power cut? Check other appliances and if
necessary, contact local Electric Supply Co.
1.2.1
Have unit checked by suitably qualified
electrician or contact Customer Service.
2.1.1
Switch off the electric supply, remove the
shower cover and plug in ribbon cable.
2.2.1
Contact Customer Service.
3.1.1
Turn temperature control anti-clockwise.
3.2.1
Contact Customer Service.
4.1.1
Clean showerhead. Check inlet filter.
4.2.1
Check connections on PCB.
4.3.1
Contact Customer Service.
5.1.1
Turn temperature control clockwise.
5.2.1
Contact Customer Service.
5.3.1
The thermal safety cut-out device has
operated. Have unit checked by suitably qualified
electrician or contact Customer Service.
6.1.1
Wait until water pressure has returned to
normal.
6.2.1
Check and clean outlet and/or
showerhead.
6.3.1
Check connection on PCB from pressure
switch.
6.4.1
Make sure the tube from solenoid valve to
pressure switch is not kinked or blocked.