Shannon electric shower
t00312
Mains cold water
supply (either top,
side, bottom
or rear entry)
Retaining
ring
Outline of bath
or shower tray
Shower unit can
be mounted either
side of riser rail
25 mm minimum
Shower unit
must not
be within
an area
1 metre
from base
Height of
showerhead
and shower
to suit user's
requirement
Fig.
Diagrammatic view (not to scale)
P-001-A
Pressure relief safety device
A pressure relief device (PRD) is designed into the
shower unit which complies with European
standards. The PRD provides a level of appliance
protection should an excessive build up of
pressure occur within the shower.
Do not operate the shower with a damaged or
kinked shower hose, or a blocked showerhead
which can cause the PRD to operate.
When commissioning, the showerhead must be
removed from the flexible hose, while at the
same time the temperature control must be at
the minimum flow position. Failure to follow this
procedure may also cause the PRD to operate.
Make sure the shower is positioned over a bath
or shower tray because if the PRD operates, then
water will eject from the bottom of the unit.
Should this happen, turn off the electricity and
water supplies to the shower at the isolating
switch and stopvalve. Contact Customer Service
for advice on replacing the PRD.
SItING OF tHE SHOWER
S-001-A
SITING OF THE SHOWER
FOR EASE OF SERVICING, THE UNIT MUST
ALWAYS BE MOUNTED ON THE SURFACE OF
TILED WALLS. NEVER TILE UP TO THE UNIT.
Refer to
(Fig. )
for correct siting of shower.
Position the unit where it will not be in direct
contact with water from the showerhead.
Position the shower unit vertically.
Allow enough room between the ceiling and the
shower to access the cover top screws.
Note:
Water Regulations (shower hose
connections) requires the showerhead be
‘constrained by a fixed or sliding attachment so
that it can only discharge water at a point not
less than 25 mm above the spill-over level of the
relevant bath, shower tray or other fixed
appliance’. The use of the supplied soap dish will
in most cases meet this requirement, but if the
showerhead can be placed within a bath, basin
or shower tray, then a double check valve, or
similar, must be fitted in the supply pipework to
prevent back-flow.
W-008-A
WARNING!
The shower must not be positioned
where it will be subjected to freezing
conditions.
I-002-A
IMPORTANT:
The unit must be mounted on
a flat surface which covers the full width
and length of the backplate. It is important
that the wall surface is flat otherwise
difficulty may be encountered when fitting
the cover and subsequent operation of the
unit may be impaired.