Страница 1: ...Rosato Entry Points H 327mm W 215mm D 94mm Diagram Key Dimensions Water Entry Points Cable Entry Points ...

Страница 2: ...ation and keep it for future reference The shower installation MUST be carried out by a suitably qualified person in the sequence of this instruction book Installation and operating instructions INSTALLERS PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER ROSATO electric shower 2181134B June 2015 ...

Страница 3: ...e videos that cover electric shower basics before your installation videos may not show the exact model purchased What is an electric shower Electrical requirements for electric showers Plumbing requirements for electric showers Kilowatt ratings explained To view these videos visit www tritonshowers co uk triton products product videos aspx SECTION SECTION SECTION SECTION SECTION SECTION SECTION S...

Страница 4: ... pipes or fittings within 300mm of the shower unit as heat can transfer along the pipework and damage components 2 4 DO NOT fit any form of outlet flow control as the outlet acts as a vent for the heater can 2 5 DO NOT use excessive force when making connections to the flexible hose or showerhead finger tight is sufficient 2 6 All plumbing connections must be completed before making the electrical...

Страница 5: ...ar to or below the minimum level The drop in pressure may be due to water being drawn off at other points in the house whilst the shower is in use If pressure drops appreciably below the minimum the heating elements will automatically cut out NOTE If ever the water becomes too hot and you cannot obtain cooler water first check that the sprayplate in the showerhead has not become blocked DO NOT pla...

Страница 6: ...TO USERS CLEANING ADVICE SPECIFICATIONS 2 DIMENSIONS CABLE WATER ENTRY POINTS 3 ELECTRICAL REQUIREMENTS 4 5 INSTALLING THE SHOWER 6 14 Siting of the shower 6 7 Plumbing installation 8 Electrical installation 9 Fit to the wall connect shower supplies 9 11 Fitting the cover 12 COMMISSIONING PROCEDURE 13 14 Connecting the PCB cable 14 USER OPERATING INSTRUCTIONS 15 17 Operating functions 17 Cleaning ...

Страница 7: ...e for 10 5kW Maximum static pressure 1000 kPa 10 bar Maximum inlet temperature 28 C Minimum inlet temperature 2 C Inlet connection 15mm diameter Outlet connection BSP male thread MATERIALS ABS Backplate cover controls showerhead Acetal Sprayplate Minerally insulated corrosion resistant metal sheathing Elements STANDARDS and APPROVALS Splashproof rating IPX4 Safety Complies with the requirements of...

Страница 8: ...4mm 327mm ENTRY POINTS DIMENSIONS WATER Right Bottom back Bottom Bottom side Left None CABLE Right Middle back Top Left None Back Back Others Others PLEASE NOTE Deviation from the approved entry points will invalidate product specifications and warranty Rosato Rosato ...

Страница 9: ...f in any doubt switch off the whole installation at the mains supply and remove the correct fuse 3 The shower must be connected to its own independent electrical circuit IT MUST NOT be connected to a ring main spur socket outlet lighting circuit or cooker circuit 3 1 The electrical supply must be adequate for the loading of the unit and existing circuits 4 Check your consumer unit main fuse box ha...

Страница 10: ...ng in a bath or shower cubicle It should be readily accessible to switch off after using the shower 7 Where shower cubicles are located in any rooms other than bathrooms all socket outlets in those rooms must be protected by a 30mA RCD 8 The current carrying capacity of the cable must be at least that of the shower circuit protection see Table B 8 1 To obtain full advantage of the power provided b...

Страница 11: ...ting to achieve your preferred shower temperature Fig 5 shows a typical system layout Refer to fig 6 for the correct siting of the shower Position the unit where it will NOT be in direct contact with water from the showerhead Position the shower unit vertically Allow enough room between the ceiling and the shower to access the cover top screws Mark out entry points and routing of the water and ele...

Страница 12: ...a blocked showerhead This may cause the PRD to operate When commissioning the showerhead must be removed from the flexible hose Failure to follow this procedure may cause the PRD to operate Make sure the shower is positioned over a bath or shower tray If the PRD operates then water will eject from the bottom of the unit Should this happen turn off the electricity and water supplies to the shower a...

Страница 13: ...he surface of the wall This area MUST be left clear when plastering and tiling around the pipework in order to make the nut accessible for future adjustments NOTE An additional stopvalve complying with Water Regulations must be fitted in the mains water supply to the shower as an independent means of isolating the water supply should maintenance or servicing be necessary IMPORTANT Before completin...

Страница 14: ...ICAL INSTALLATION 6 check list SECTION Installation FIT TO THE WALL CONNECT THE SHOWER SUPPLIES FIT TO THE WALL CONNECT THE SHOWER SUPPLIES Pipe Electrical access points If bottom or right surface entry is required for the mains cold water then the necessary opening will need to be cut out in the cover and the trimplate fig 8 If surface cable entry from the top is required then a small area will n...

Страница 15: ... adjustment after the plumbing connections have been completed Connect the mains water supply to the inlet DO NOT use excessive force when making the connection Make sure the backplate is square on the wall and tighten the retaining screws which hold it to the wall Turn on the mains water supply and check for leaks in the pipework connection to the shower NOTE At this stage no water can flow throu...

Страница 16: ...supply cable must be stripped back to the minimum The use of connections within the unit or other points in the shower circuit to supply power to other equipment i e extractor fans pumps etc will invalidate the guarantee DO NOT switch on the electricity supply until the shower cover has been fitted 7 Continued SECTION NOTE The elements on UK models are to 240V specification and will give a lower k...

Страница 17: ...ficulty arise recheck the points above While applying slight pressure to the front cover secure in position with the retaining screws Fit the flexible hose to the shower outlet making sure the outlet of the hose is directed to waste Check the supplied sealing washer is in place DO NOT attach the showerhead at this stage PLEASE NOTE Before normal operation of the shower it is essential the followin...

Страница 18: ...se the PRD to operate Turn on the water supply to the shower at the isolating stop valve Switch on the electricity supply to the shower at the isolating switch Wait until water starts to flow from the flexible hose Slowly rotate the temperature control fully anti clockwise as in fig 16 It will take about thirty seconds for a smooth flow of water to be obtained while air and any debris is being flu...

Страница 19: ...the socket in one way The ribbon cable has a coloured edge which is lowermost when correctly fitted to the socket Guide the cover into position so that the knob spindle locates correctly minor adjustment may be necessary to align the knob and spindle Should any difficulty arise re check the points above While applying slight pressure to the cover secure in position with the retaining screws Turn t...

Страница 20: ... temperature This setting should normally be regarded as optimum shower performance throughout the year The ECONOMY setting uses less energy when the ambient mains water temperature is high during hot months The HIGH ECONOMY button alternates between the two settings press the button once to select the ECONOMY setting press the button again to reselect HIGH Temperature adjustment at this setting i...

Страница 21: ...ges in ambient water temperature NOTE The preferred knob position on ECONOMY will give a different temperature to the same position on HIGH To decrease the shower temperature Turn the temperature control anti clockwise this will increase the flow of water through the shower and make the water colder To increase the shower temperature Turn the temperature control clockwise this will decrease the fl...

Страница 22: ...ights when the button is pressed indicating which shower mode is in operation On the high setting both indicators next to the button are lit On the economy setting only the lower of the two indicators is lit Phased shutdown In use every time the Stop button is pressed power is switched off to the elements Water will continue to flow for a few seconds flushing out any remaining hot water This makes...

Страница 23: ...access to the filter remove the trimplate and then unscrew the retaining nut from the bottom of the inlet pipe When cleaning the filter DO NOT use a sharp object as it will cause damage It is preferable to use an old toothbrush or similar To reassemble follow the procedure in reverse DO NOT over tighten the fittings on reassembly Instructions for installers and service engineers only INSTRUCTIONS ...

Страница 24: ...y 2 2 1 Check if stop valves are fully open Check if a blockage in the inlet filter 2 3 Increase in ambient water temperature 2 3 1 Readjust flow rate to give increased flow 2 3 2 Select economy power 3 Water too cool or cold 3 1 Too much flow 3 1 1 Reduce flow rate via temperature control 3 2 Water pressure below minimum required see rating label 3 2 1 Is water supply mains or tank fed 3 2 2 If t...

Страница 25: ...3 5 1 Thermal safety cut out device has operated Have the unit checked by a suitably qualified engineer or contact Customer Service 4 Pressure relief device has operated water ejected from PRD tube 4 1 Blocked showerhead 4 1 1 Clean sprayplate and then fit a new PRD 4 2 Twisted blocked flexible shower hose 4 2 1 Check for free passage through hose Replace hose if necessary and then fit new PRD 4 3...

Страница 26: ... 5kW P12120705 4 Stabiliser valve solenoid P12120801 assembly 5 Thermal cut out 22011180 6 Pressure relief device PRD 82800450 7 Outlet pipe assembly S12711003 8 Inlet assembly S12721002 9 Trimplate white 7053967 Black 7054026 10 Cover assembly including cover PCB White Brushed steel effect S80000040 Chrome Black S80000041 Stop switch assembly 82301360 9 8 7 6 5 4 3 2 1 10 Rosato ...

Страница 27: ...nder the following schemes Repic Producers take back scheme PTS registration number WEE EJ3466QV Valpak Distributor take back scheme DTS registration number 9659 All our electric products are labelled accordingly with the crossed out wheeled bin symbol This indicates for disposal purposes at end of life that these products must be taken to a recognised collection points such as local authority sit...

Страница 28: ...EMENTS USED 2 OF THE ELEMENTS USED 0 1 2 H O T HOT COLD To START the shower press the Start Stop button The power light will illuminate 1 3 4 To STOP the shower press the Start Stop button then turn the isolator switch off 2 HIGH heat both lit COLD water HOT COLD 0 1 2 HEATER ELEMENTS USED NONE OF THE ELEMENTS USED HOT COLD HEATER ELEMENTS USED 0 1 2 1 OF THE ELEMENTS USED ECONOMY heat bottom lit ...

Страница 29: ...20 6 33 530 35 6 176 480 168 UNBMXFIXBT All dimensions listed regarding the product and installation are approximate Please read the fitting instructions before proceeding ...

Страница 30: ...Slider holder assembly Press and hold button to unlock mechanism Riser rail Fig 1 Fig 3 Fig 2 ...

Страница 31: ...Washers Shower Showerhead Showerhead Holder Fig 4 Fig 5 Fig 6 Fig 7 ...

Страница 32: ...A B C D F D E ...

Страница 33: ...ls including post code the model number and power rating of the product together with the date of purchase and where applicable details of the particular fault 2 If required the Customer Service Advisor will arrange for a qualified engineer to call 3 All products attended to by a Triton service engineer must be installed in full accordance with the Triton installation guide applicable to the produ...

Страница 34: ...2180872D July 2014 Maintenance Instructions INSTALLERS PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER 8000 Series Showerhead 32mm ...

Страница 35: ... the spray plate clockwise until it reaches it s stop position facing the removal button 2 Press and hold the removal button in 3 With the removal button held in rotate the face plate clockwise past the removal button until it stops 4 Release the removal button and gently pull the face plate away from the body using the adjustment lever Removal button Body Spray plate 1 2 3 4 IMPORTANT Should any ...

Страница 36: ...se do the following a Ensure that the inner plate is turned fully clockwise until it stops The alignment arrow position is approximately 9 o clock when the showerhead is in the vertical position b The lever MUST then be matched up with the arrows position to reinstall the spray plate correctly Should any difficulty arise when trying to refit the spray plate DO NOT try to force it back into positio...

Страница 37: ...N MIXER electric showers only 88500062 INCLUSIVE WHT 88500069 ELEC SATIN 88500070 INCLUSIVE CHROME 88500074 ELEC WHITE 88500075 ELEC CHROME 2 Flow Regulator FLOW REGULATORS 22011740 4 L MIN 22011750 5 L MIN 22011760 6 L MIN 22011610 7 L MIN 22011280 8 L MIN SPARE PARTS For latest service policy and contact details visit www tritonshowers co uk 1 2 ...