Bar Mixer Shower
11
BRACKET INSTALLATION
This guide contains all the necessary fitting
instructions for your (built-in pipework, push-fit
connector) bar mixer bracket. The bracket has
been designed to be surface mounted, using
15mm pipework and can be used with bar
mixers or bath shower mixers with ¾’’ BSP
fixings.
Please read the instructions carefully.
Read through the whole of this guide before
beginning installation.
The bracket installation must be carried out by a
suitably competent person and in the sequence
of the instruction book.
Care taken during the installation will provide
trouble free operation from the bracket.
SAFETY WARNINGS
a.
Layout and sizing of pipework must be such
that when other services are used, pressures
at the mixer control inlets do not fall below
the recommended minimum.
b.
DO NOT choose a position where the
mixer shower could become frozen.
c.
DO NOT connect to any form of tap
or fitting not recommended by the
manufacturer.
d.
Conveniently situated service valves in each
inlet supply must be fitted as an independent
method of isolating the bracket should
maintenance or servicing be necessary.
Refer to the mixer installation guide for further
information.
Replacement parts can be ordered from
Customer Experience.
WARNING
The threads of number 6 (push-fit connector)
are sharp. The use of gloves or a suitable rag
is recommended when handling the item,
to avoid being cut by the threads.
WARNING!
Check there are no hidden cables or
pipes before drilling holes for wall plugs.
Use great care when using power tools
near water. The use of a residual current
device (RCD) is recommended.
T00364
Fig.8
1
3
5
2
4
6
7
*
If supplied
*
1.
Cover trim x2
2.
Mounting plate and grub screw x2
3.
Plastic seal x2
4.
Flow regulator x2
5.
Filter x2
6.
Push-fit connector x2
7.
Locking clip x2