Bar Mixer Shower
15
T00358
T00359
T00360
Filter
Plastic
seal
Fig.18
Fig.19
Align the mounting plate fixing holes to the
intended position and mark the holes.
Remove the mounting plate. If necessary,
hold the push-fit connector stationary when
unscrewing the mounting plate.
Drill and plug the wall. An appropriate drill bit
should be used. If the wall is brick, plasterboard
or a soft building block, appropriate wall plugs
and screws should be fitted.
Re-assemble the mounting plate onto the push-
fit connector and secure the mounting plate to
the wall.
Insert the grub screw into the mounting plate
and tighten to secure the connector
(fig.17)
.
Using a suitable sealant, seal the join between
the mounting plate and the wall or tiles to
prevent water entering the wall
(fig.17)
. Wipe
away any excess sealant which may obstruct the
fitting of the cover trim.
Push-fit the cover trims onto the mounting
plates. A smear of liquid soap on the seal will
ease this procedure
(fig.18).
Fit the seals into the push-fit connector outlets
(fig.19)
.
Fit and secure the bar mixer to the connectors.
LEAK TESTING THE MIXER
IMPORTANT:
Flush out the pipework in
accordance with Water Regulations and
Bylaws.
Without the showerhead fitted, fit the hose to
the outlet and direct it to waste.
Open the water isolating valves to the shower
and check for leaks.
If any leaks are found, rectify them before
carrying out the commissioning procedure.
Fig.17