Bar mixer shower
20
Problem/Symptom Cause
Action/Cure
The following can be carried out by a competent person
FAULT FINDING
1
Water too hot.
2
Water too cold.
3
High water flow
and/or poor
performance on a
mains fed system.
1.1
Temperature control
incorrectly commis-
sioned.
1.2
Not enough cold
water flowing through
shower.
1.3
Increase in the
ambient cold water
temperature.
1.4
Cold water supply
blocked.
1.5
High volume of cold
water drawn off else-
where.
2.1
Temperature control
incorrectly commis-
sioned.
2.2
Not enough hot
water flowing through
shower.
2.3
Decrease in the
ambient cold water
temperature.
2.4
Insufficient hot water
supplies from the heat-
ing system.
2.5
Hot water supply
blocked or restricted.
2.6
Flow regulator not fit-
ted (HP systems only).
3.1
Flow regulators not
fitted.
1.1.1
Refer to commissioning section.
1.2.1
Reposition temperature control knob
1.3.1
Reposition temperature control knob.
1.4.1
Turn off the shower and consult a compe-
tent plumber or contact Moretti Customer
Service.
1.5.1
Reduce the simultaneous demand from the
supply.
2.1.1
Refer to commissioning section.
2.2.1
Reposition temperature control knob
2.3.1
Reposition temperature control knob
2.4.1
Make sure heating appliance is set to maxi-
mum or has sufficient stored hot water.
2.4.2
Make sure heating appliance is igniting by
trying a hot water tap elsewhere.
2.5.1
Turn off shower and consult a competent
plumber or contact Moretti Customer
Service.
2.6.1
Contact customer service.
3.1.1
Contact customer service.
Содержание Bar Mixer Shower With Diverter
Страница 4: ...Bar mixer shower 2 DIMENSIONS 131 96 111 45 150 283 ...