background image

FA/May 10

Arc Enclosure

Instruction Manual

1. Check you have the correct enclosure and tray. Please look at the labels on the side of the product packaging.
2. Check all the product components are in the box and the fixing kits are complete. Please check this with the component

check list overleaf.

3. Unpack your product and handle it with care.
4. Please check the product for defects or damage. Once the installation has commenced we cannot accept responsibility for

any defects or damage to the products.

5. Please take the time to read these instructions prior to installing your product.
6. Before you commence any drilling check there are no hidden electrical cables and/or water pipes in the walls.
7. No attempt should be made to re-work the toughened safety glass.
8. The installation should be performed by two persons.
9. It is strongly recommended the walls the product is going to be installed on are vertical. However the wall profiles have

25mm of adjustment to help compensate for some deviation.

10. It is strongly recommended the product is fitted on tiled surface or similar waterproof surface.
11. It is strongly recommended the walls are tiled and grouted after the installation of the tray and before the installation of the

product. This will provide maximum adjustment and help when sealing the product.

12. If the walls and/or the tray are not level you will not achieve maximum adjustment of the product.
13. Pictures used are for illustration purposes only, product designs may alter slightly as a result of continuing product

development.

14. We do not stipulate where the European Standard Kite Mark should be positioned on the glass panels when being factory

assembled.

IMPORTANT INFORMATION

Roman’s toughened glass is completely safe for use in our shower enclosures and bath screens; providing our products are
installed according to our guidelines.

It is important to note, that the glass must not be mounted or ‘pinched’ in such a way that would cause a stress point to
develop in the glass. In addition, it must not be subjected to any sharp impact or severe temperature fluctuation which may
also cause a stress point to develop in the glass.

Roman’s toughened glass is physically and thermally significantly stronger than standard glass. During our toughening
process the stresses contained within any glass are balanced so if in the unlikely situation any of the above occurs and the
glass breaks, the glass will shatter safely into small thumbnail sized blunt fragments.

IMPORTANT PRE-INSTALLATION CHECKS

Important: If you are fitting this product with integrated water delivery, the valve must be installed before

tiling the showering area and before the installation of this product.

FA

Consumer Guarantee -

Please make sure the purchaser/end user completes and returns the Guarantee card

which is enclosed with this product. Failure to validate the Guarantee will mean only the 1 Year Statutory Guarantee will apply.

FA - Freedom Arc Dec 2009:CQB

4/5/10

12:05

Page 1

Summary of Contents for Arc Enclosure

Page 1: ... adjustment of the product 13 Pictures used are for illustration purposes only product designs may alter slightly as a result of continuing product development 14 We do not stipulate where the European Standard Kite Mark should be positioned on the glass panels when being factory assembled IMPORTANT INFORMATION Roman s toughened glass is completely safe for use in our shower enclosures and bath sc...

Page 2: ...ons When all of the above criteria is complete please proceed to the next step in these instructions Step 1 Checking the tray Component Check List Supplied Description Quantity Front Panel 1 Hinge Panel 1 Door 1 Wall Profiles 2 Wall Profile Trims 2 Handle Assemblies 1 Hinge Assemblies 2 Brace Bar Assembly 2 Door Bottom Seal 1 Fixing Kit Component Check list 40 mm Screws 8 Wall Plugs 8 16mm Pan Hea...

Page 3: ...masonry bit not supplied Then push the wall plugs in beyond the depth of the tile 4 Apply sealant the width of the wall profiles where they meet the tiles and the tray Important failure to carry out this procedure can cause serious water damage and is not covered by the guarantee 5 Fix the Wall Profiles using the 40 mm screws supplied 6 Apply Sealant to the inside of the wall profiles where they m...

Page 4: ... vertical and drill through the pre drilled holes of the wall profile using the 3mm drill bit supplied 5 Fix the panel to the wall profile using the 16mm pan head screws supplied The panel must be completely vertical the bubble should be in the centre of the 2 lines on the spirit level 6 Fit the remaining panel by following steps1 to 5 as previously done You may need help to perform the installati...

Page 5: ... drilled 5 Drill the location hole for the wall cup using a 6mm masonry drill not supplied and insert the wall plug 6 Fix the brass insert to the wall using the 40mm screws supplied and then screw the wall cup onto the brass insert so that it is tight up to the tiled walls 7 Assemble the bracing bar back onto the panel and into the wall cup No metal should touch the glass the spacers must be used ...

Page 6: ...ards the hinge panel and into location on the hinges Make sure the panel seal flap sits behind the door glass Assemble the hinges onto the door There should be no metal touching the glass The spacers must be used Lightly tighten the hinge bolts using an Allen Key 5 Make sure the door deflector seal is locating its full length horizontally along the tray 6 Align the hinges so they are at 90 degrees...

Page 7: ...he full length of the wall profiles where they meet the tiles on the outside of the enclosure using bathroom sealant 6 Seal horizontally the aluminum profiles and the glass panels on the outside of the enclosure at the bottom where they meet the tiles and the tray using bathroom sealant Please leave the sealant 24hrs to cure before use IMPORTANT Failure to follow the procedure in steps 5 and 6 can...

Page 8: ...r Glass 10 RMC0076 Silver 2 Freedom Hinge 11 RG0130 Clear 1 Vertical Door Seal C1064 12 RIM0206 Chrome 1 Vertical Cover Cap R H 13 RIM0210 Chrome 1 Screw Cover Cap R H 14 RSCR48 Grey 2 Plastic Tray Pin 15 N A N A 1 Large Panel Assembly 16 RMC0069 Silver 1 New Orbital Handle 240mm Centres 17 RGO149 Clear 1 Bottom Seal 18 N A N A 1 Small Panel Assembly Spare Parts If you require any spare parts plea...

Page 9: ...d the glass panels step 3 and 5 1 In order to use the location pins follow the measurements above to determine the positions 2 Drill a 9 mm diameter hole with a recommended depth of 10mm using suitable a drill bit 3 Screw the location pins into the bottom of the aluminum profiles on the glass panels 4 Continue with the installation by following the instructions Caution Before you commence any dril...

Page 10: ...tray installation OPERATING 2 Check the tray is level Step 1 SMOOTHLY 3 Check the wall profiles have been fitted as per the instructions 4 Make sure they are vertically level Step 2 5 Check the panels have been fitted as per the instructions 6 Make sure they are vertically and horizontally level Step 3 7 Check the hinges have been fitted as per the instructions 8 Check the hinges are level Step 5 ...

Reviews: