WIT042 V1.1-01NR
15
We recommend a frequent cleaning of the device. Please use a moist, lint-free cloth. Never
use alcohol or solvents!
The objective lens will require weekly cleaning as smoke-fluid tends to building up residues,
reducing the light-output very quickly. The cooling-fans should be cleaned monthly.
The gobos may be cleaned with a soft brush. The interior of the fixture should be cleaned at
least annually using a vacuum-cleaner or an air-jet.
The dichroic color-filters, the gobo-wheel and the internal lenses should be cleaned
monthly.
To ensure a proper function of the gobo-wheel, we recommend lubrication in six month
intervals. The quantity of oil must not be excessive in order to avoid that oil runs out when
the gobo-wheel rotates.
There are no serviceable parts inside the device. Maintenance and service operations are
only to be carried out by authorized dealers.
Please refer to the instructions under "Installing/Replacing the lamp".
Replacing the fuse
If the fine-wire fuse of the device fuses, only replace the fuse by a fuse of same type and
rating.
Before replacing the fuse, unplug mains lead.
Procedure:
Step 1:
Open the fuse holder on the rear-panel with a fitting screwdriver.
Step 2:
Remove the old fuse from the fuse-holder.
Step 3:
Install the new fuse in the fuse-holder.
Step 4:
Replace the fuse-holder in the housing.
Should you need any spare parts, please use genuine parts.
If the power supply cable of this device becomes damaged, it has to be replaced by a
special power supply cable available at your dealer.
Should you have further questions, please contact your dealer.