Optional Connections 

(continued)

USB and RS-232 Serial 

Communications

Use the included USB cable (see 

2a

) and/or DB9 

serial cable (see 

2b

) to connect the UPS to a Media 

Center  PC,  home  automation  system  or  server. 
Install the Tripp Lite PowerAlert Software appropriate 
to  your  equipment's  operating  system.  Your  UPS 
may feature two communication ports; the additional 
port  can  be  used  to  connect  the  UPS  to  a  second 
home entertainment or home automation PC that has 
PowerAlert Software installed. For more information, 
consult your PowerAlerts manual.

EPO Port Connection  

(Select Models)

 This  optional  feature  is  only  for  those  applications 
that require connection to a home automation/home 
security Emergency Power Off (EPO) circuit. When 
the  UPS  is  connected  to  this  circuit,  it  enables 
emergency  shutdown  of  the  UPS's  inverter.  Using 
the  cable  provided,  connect  the  EPO  port  of  your 
UPS (see 

3a

) to a user-supplied normally closed or 

normally  open  switch  according  to  the  circuit 
diagram  (see 

3b

).  The  EPO  port  is  not  a  phone 

line surge suppressor; do not connect a phone line 
to this port.

External Battery Connection 

Check  to  ensure  that  the  external  batteries  you  are 
connecting  match  the  voltage  listed  on  your  UPS's 
battery  connector.  All  UPS  models  come  with  a 
robust  internal  battery  system;  all  models  feature 
connectors  that  accept  optional  external  battery 
packs  (sold  separately  from  Tripp  Lite)  to  provide 
additional  runtime.  Adding  external  batteries  will 
increase  recharge  time  as  well  as  runtime.  See  the 
battery pack owner's manual for complete installation 
instructions. Make sure cables are fully inserted into 
their  connectors.  Small  sparks  may  result  during 
battery connection; this is normal. Do not connect or 
disconnect  battery  packs  when  the  UPS  is  running 
on battery power.

2

3

CAUTION

Risk of electric shock
See top of unit for cautionary markings

WARNING

CONNECT 48 VDC

BATTERY SYSTEMS ONLY

CONNECTING OTHER

SYSTEMS WILL VOID

WARRANTY

30A

48V/26A

2b

4

Your model may differ.

Your model may differ.

Installation 

(continued)

4

CAUTION

Risk of electric shock
See top of unit for cautionary markings

WARNING

CONNECT 48 VDC

BATTERY SYSTEMS ONLY

CONNECTING OTHER

SYSTEMS WILL VOID

WARRANTY

30A

2a

Your model may differ.

CAUTION

Risk of electric shock
See top of unit for cautionary markings

WARNING

CONNECT 48 VDC

BATTERY SYSTEMS ONLY

CONNECTING OTHER

SYSTEMS WILL VOID

WARRANTY

30A

3a

Your model may differ.

4-5

3b

200907169  93-2615.indd   5

8/11/2009   10:15:01 AM

Содержание SmartOnline 2-9USTAND

Страница 1: ...Systems Intelligent True On Line Operation Pure Sine Wave Output Zero Transfer Time 1000VA 2200VA Capacities Extended Run Options Warranty Registration 12 Copyright 2009 Tripp Lite All rights reserve...

Страница 2: ...d is sized properly by using properly gauged wire and properly connected by having a 3 prong grounded plug on one end and a 3 prong receptacle on the other end of this cord The UPS itself must be dire...

Страница 3: ...tach mounting ears D to the front mounting holes of your equipment E using the screws provided F The ears should face forward Using an assistant if necessary lift your equipment and slide it onto the...

Страница 4: ...conds until you hear a beep Release it Your UPS will begin providing AC power to its outlets The ON LINE LED will illuminate Note The UPS system will function properly upon initial startup however max...

Страница 5: ...rnal batteries you are connecting match the voltage listed on your UPS s battery connector All UPS models come with a robust internal battery system all models feature connectors that accept optional...

Страница 6: ...rging and the fan will continue to cool internal components even after you turn the UPS receptacles off To turn the UPS OFF completely including the charger disconnect the UPS s power cord after press...

Страница 7: ...four dual function LEDs is displaying the load level of your UPS BATT ACTIVE METER LED This green light will illuminate when your UPS is operating from battery power to indicate that the set of four...

Страница 8: ...ustomer Support at 773 869 1234 for the appropriate Tripp Lite battery pack to connect Refer to instructions available with the Battery Pack for complete connection information and safety warnings Fan...

Страница 9: ...PowerAlert Software and the appropriate cable did not come with your UPS you can obtain the software FREE via the Web at www tripplite com Any user supplied DB9 pass through or USB cable may then be u...

Страница 10: ...YPASS LINE Restart the UPS If the problem persists Flashing 25 contact Tripp Lite for repairs Condition On Bypass due to Low Bus Voltage On BYPASS LINE Check the UPS to be sure that there is Flashing...

Страница 11: ...wer cord from the wall outlet Next disconnect all equipment to avoid battery drain If you plan on storing your UPS for an extended period of time fully recharge the UPS batteries once every three mont...

Страница 12: ...the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can r...

Отзывы: