“REPLACE BATT” LED: This red light will illuminate constantly and the 
UPS alarm will beep every 2 seconds if your UPS’s microprocessor detects a 
battery fault or if your UPS fails the automatic self-test (after you turn your 
UPS ON) and the UPS battery is less than fully charged. Let the UPS system 
charge  for  at  least  12  hours  and  perform  a  self  test  using  the  “ON/TEST 
Button” as described on page 6. If the light continues to stay on, contact Tripp 
Lite for service.
 
 
 
Accessory Slot: Remove the small cover panel from this slot to use optional 
accessories  to  remotely  monitor  and  control  your  UPS.  Contact  Tripp  Lite 
Customer Support at (773) 869-1234 for more information, including a list of 
available SNMP, network management and connectivity products.

External Battery Pack Connector (configuration varies by model): Use to 
connect  optional  Tripp  Lite  Battery  Packs  for  additional  runtime.  Contact 
Tripp Lite Customer Support at (773) 869-1234 for the appropriate Tripp Lite 
battery pack to connect. Refer to instructions available with the Battery Pack 
for complete connection information and safety warnings.

Fan: The fan cools the UPS’s internal components. It is always on when line 
power is present.

Input Circuit Breaker Switch: This resettable breaker prevents high input 
current  from  damaging  the  UPS  or  the  attached  load.  If  this  breaker  trips, 
make sure your UPS is connected to AC power of the proper voltage before 
resetting the circuit breaker by pushing the breaker switch in.

Ground  Screw:  Use  this  to  connect  any  equipment  that  requires  a  chassis 
ground.

Output  Circuit  Breakers  Switches  (HTR22-3U):  These  resettable  circuit 
breakers protect your UPS from output overload. If one or both breakers trip, 
remove some of the load on the circuit(s) and allow the UPS to cool before 
pressing the breaker switch(es) in to reset.

Input Cord: This permanently attached power cord connects your UPS to a 
power outlet.

Front Panel Indicator Lights 

continued

Basic Operation 

(continued)

8

200907169  93-2615.indd   8

8/11/2009   10:15:04 AM

Содержание SmartOnline 2-9USTAND

Страница 1: ...Systems Intelligent True On Line Operation Pure Sine Wave Output Zero Transfer Time 1000VA 2200VA Capacities Extended Run Options Warranty Registration 12 Copyright 2009 Tripp Lite All rights reserve...

Страница 2: ...d is sized properly by using properly gauged wire and properly connected by having a 3 prong grounded plug on one end and a 3 prong receptacle on the other end of this cord The UPS itself must be dire...

Страница 3: ...tach mounting ears D to the front mounting holes of your equipment E using the screws provided F The ears should face forward Using an assistant if necessary lift your equipment and slide it onto the...

Страница 4: ...conds until you hear a beep Release it Your UPS will begin providing AC power to its outlets The ON LINE LED will illuminate Note The UPS system will function properly upon initial startup however max...

Страница 5: ...rnal batteries you are connecting match the voltage listed on your UPS s battery connector All UPS models come with a robust internal battery system all models feature connectors that accept optional...

Страница 6: ...rging and the fan will continue to cool internal components even after you turn the UPS receptacles off To turn the UPS OFF completely including the charger disconnect the UPS s power cord after press...

Страница 7: ...four dual function LEDs is displaying the load level of your UPS BATT ACTIVE METER LED This green light will illuminate when your UPS is operating from battery power to indicate that the set of four...

Страница 8: ...ustomer Support at 773 869 1234 for the appropriate Tripp Lite battery pack to connect Refer to instructions available with the Battery Pack for complete connection information and safety warnings Fan...

Страница 9: ...PowerAlert Software and the appropriate cable did not come with your UPS you can obtain the software FREE via the Web at www tripplite com Any user supplied DB9 pass through or USB cable may then be u...

Страница 10: ...YPASS LINE Restart the UPS If the problem persists Flashing 25 contact Tripp Lite for repairs Condition On Bypass due to Low Bus Voltage On BYPASS LINE Check the UPS to be sure that there is Flashing...

Страница 11: ...wer cord from the wall outlet Next disconnect all equipment to avoid battery drain If you plan on storing your UPS for an extended period of time fully recharge the UPS batteries once every three mont...

Страница 12: ...the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can r...

Отзывы: