Service

If you are returning your Inverter/Charger to Tripp Lite, please pack it carefully, using the ORIGINAL PACKING MATERIAL that came
with the unit. Enclose a letter describing the symptoms of the problem. If the Inverter/Charger is within the warranty period, enclose a copy
of your sales receipt. To obtain service you must obtain a Returned Material Authorization (RMA) number from Tripp Lite or an authorized
Tripp Lite service center. 

Your Inverter/Charger requires no maintenance and contains no user-serviceable or replaceable parts, but should be kept dry at all times.
Periodically check, clean and tighten all cable connections, as necessary, both at the unit and at the battery.

Try these remedies for common Inverter/Charger problems before calling for assistance. Call Tripp Lite Customer Service at (773) 869-1234
before returning your unit for service.

Maintenance

Troubleshooting

SYMPTOM

PROBLEMS

CORRECTIONS

No AC Output

Unit is not properly connected to utility power

Connect unit to utility power.

(All Indicator Lights are OFF)

Operating Mode Switch is set to “OFF” and AC input

Set Operating Mode Switch to “AUTO/REMOTE” or “CHARGE ONLY”.

is present.

This is normal when the Operating Mode Switch is set to

No correction is required. AC output will return when AC input 

“CHARGE ONLY” and AC input is absent.

returns. Set Operating Mode Switch to “AUTO/REMOTE” if you
require AC output.

Circuit breaker is tripped.

Reset circuit breaker.

Unit has shut down due to battery overcharge (preventing

Disconnect any auxiliary chargers. Reset by moving Operating Mode

battery damage). The problem may be with connected

Switch to “OFF”. Wait 1 minute and switch to “AUTO/REMOTE” or

auxiliary chargers, if any, or with the unit’s charger.

“CHARGE ONLY.” If unit remains in shutdown mode after several
attempts to reset, contact Tripp Lite Customer Service for assistance.

Unit has shut down due to excessive battery discharge.

Use an auxiliary charger* to raise battery voltage. Check external
battery connections and fuse. Unit automatically resets when
condition is cleared.

Unit has shut down due to overload.

Reduce load. Reset by moving Operating Mode Switch to “OFF”.
Wait 1 minute. Switch to “AUTO/REMOTE” or “CHARGE ONLY”.

Battery Not Recharging

Connected batteries are dead.

Check and replace old batteries.

(AC Input Present)

Battery fuse* is blown.

Check and replace fuse.*

Battery cabling* is loose.

Check and tighten or replace cabling.*

Unit has shut down due to battery overcharge (preventing

Disconnect any auxiliary chargers. Reset by moving Operating Mode

battery damage). The problem may be with connected

Switch to “OFF”. Wait 1 minute and switch to “AUTO/REMOTE” or

auxiliary chargers, if any, or with the unit’s charger.

or “CHARGE ONLY.” If unit remains in shutdown mode after several
attempts to reset, contact Tripp Lite Customer Service for assistance.

Input circuit breaker is tripped.

Reset circuit breaker.

All Three Battery Indicator Lights

Battery is excessively discharged.

Use an auxiliary charger* to raise battery voltage. Check external

Are Slowly Flashing.

battery connections and fuse. Unit automatically resets when

(½ Second Flashes)

condition is cleared.

All Three Battery Indicator Lights

Battery is overcharged. Unit will shut down to prevent

Disconnect any auxiliary chargers. Reset by moving Operating Mode

Are Rapidly Flashing

battery damage. The problem may be with connected auxiliary

Switch to “OFF”. Wait 1 minute and switch to “AUTO/REMOTE” or

(¼ Second Flashes)

chargers, if any, or with the unit’s charger.

“CHARGE ONLY.” If unit remains in shutdown mode after several
attempts to reset, contact Tripp Lite Customer Service for assistance.

Red “LOW” Battery

Battery voltage is low. Unit will automatically shut down

Make sure that AC power is present in order to recharge batteries.

Indicator Light Is Flashing

after 5 seconds to protect battery from damage.

Reset by moving Operating Mode Switch to “OFF then to
“AUTO/REMOTE” or “CHARGE ONLY”.

False reading due to undersized or

Use sufficient size DC cable sufficiently connected to 

insufficiently connected DC cabling.

Inverter/Charger.

Red “LOAD” Operation

Inverter is overloaded. Unit will automatically shut down

Reduce load. Reset by moving Operating Mode Switch to “OFF”.

Indicator Light flashing

after 5 seconds.

Wait 1 minute. Switch to “AUTO/REMOTE” or “CHARGE ONLY”.

* User-supplied.

OFF

(LESSER

LOAD

ON)

MAX

(GREATER

LOAD

ON)

Battery Indicator Lights

Operating Mode Switch

Operation Indicator Lights

200510095  93-2144

Содержание PowerVerter RV1012UL

Страница 1: ...remium Protection Levels Built In ISOBAR Surge Protection Automatic Overload Protection Ideal Output for All Loads including computers Frequency Controlled Output Fast Load Switching Balanced Load Sharing Better for Your Batteries Faster Battery Recharge High Amp 3 Stage Battery Charger adjustable Critical Battery Protection Battery Charge Conserver Load Sense Battery Temperature Sensing High Effi...

Страница 2: ...Hardwire Hardwire Hardwire Hardwire Hardwire Hardwire Hardwire INVERTER Common Specifications for All Models DC Input Volts Nominal 12 VDC DC Input Voltage Range 10 15 VDC Output Volts Nominal 120 VAC 5 Output Frequency Nominal 60 Hz 0 5 Efficiency 88 to 94 depending on load and temperature Select Tripp Lite Inverter Chargers include a Battery Charge Conserver Load Sense Control which saves batter...

Страница 3: ... be installed whether for a mobile or stationary application in a dead air compartment Ideally any compartment would have some ventilation to outside air Sparks may result during final battery connection Always observe proper polarity as batteries are connected Do not allow objects to contact the two DC input terminals Do not short or bridge these terminals together Serious personal injury or prop...

Страница 4: ...I receptacle output See page 11 for connection instructions Resettable Circuit Breaker protect your Inverter Charger against damage due to overload See page 5 for resetting instructions Remote Control Module Connector allows remote monitoring and control with an optional module Tripp Lite model APSRM2 sold separately or included with select models See remote module owner s manual for connection in...

Страница 5: ...erator source If the operating mode switch is set to CHARGE ONLY this light will BLINK to alert you that the unit s inverter is OFF and will NOT supply AC power in the absence of a utility generator source or in over under voltage situations INV Inverting Yellow Indicator This light will ILLUMINATE CONTINUOUSLY whenever connected equipment is receiving battery supplied inverted AC power in the abs...

Страница 6: ...o momentary high low line voltage swings that would have little effect on equipment operation you may wish to adjust these settings By increasing the High AC Voltage Point and or decreasing the Low AC Voltage Point you will reduce the number of times your unit switches to battery due to voltage swings Group B DIP Switches Not on 612 Models Select Load Sharing OPTIONAL Not on 612 Models Your Invert...

Страница 7: ...t s inverter automatically shuts off in the absence of any power demand from connected equipment or appliances the electrical load When the unit detects a load it automatically turns its inverter function on Users may choose the minimum load the Inverter Charger will detect by adjusting the Battery Charge Conserver Dial see diagram Using a small tool turn the dial clockwise to lower the minimum lo...

Страница 8: ...ve by the battery voltage 12 to determine the DC amps required STEP 3 Estimate Battery Amp Hours Required for operation unsupported by the alternator Multiply the DC amps required from step 2 above by the number of hours you estimate you will operate your equipment exclusively from battery power before you have to recharge your batteries with utility or generator supplied AC power Compensate for i...

Страница 9: ...rter Charger cabinet Install and tighten two user supplied 6 mm fasteners into the mounting feet molded on the rear of the Inverter Charger cabinet The rear feet extend beyond the unit s cabinet to provide for adequate ventilation space behind the cooling fan s they should not be removed 6 4 727 32 6 11 4 cm 17 1 cm 20 cm 17 1 cm C B M A C B M A B A B C 10 26 4 cm 3 Note RV model cabinets may have...

Страница 10: ...rical system In most vehicles the Inverter Charger will be connected to one or more dedicated auxiliary house batteries which are isolated from the drive system to prevent possible draining of the main battery 12 Volt Inverter Charger 12 Volts 12 Volts 3 5 12 Volt Main Battery Connection 12 Volt Alternator Vehicle Battery Ground 12 Volt Main Battery 12 Volt Auxiliary House Battery UL Listed Fuse F...

Страница 11: ...e on each 120V leg or two different 120V sources The Inverter Charger will only supply 120V output power and WILL NOT provide 240V output even if it is connected to inputs from a split 240V service when in inverter mode When the Inverter Charger is receiving AC power it can supply connected loads with up to 20 amps of power on each circuit When the Inverter Charger is not receiving AC power and ha...

Страница 12: ...oving Operating Mode Switch to OFF Wait 1 minute Switch to AUTO REMOTE or CHARGE ONLY Battery Not Recharging Connected batteries are dead Check and replace old batteries AC Input Present Battery fuse is blown Check and replace fuse Battery cabling is loose Check and tighten or replace cabling Unit has shut down due to battery overcharge preventing Disconnect any auxiliary chargers Reset by moving ...

Отзывы: