Important Safety Instructions

SAVE THESE  INSTRUCTIONS!

This manual contains important instructions and warnings that should be followed during the installation, operation and storage of all Tripp Lite
Inverter/Chargers.

Location Warnings

• Install your Inverter/Charger (whether for a mobile or stationary application) in a location or compartment that minimizes exposure to 

heat, dust, direct sunlight and moisture.

• Although your Inverter/Charger is moisture resistant, it is NOT waterproof. Flooding the unit with water will cause it to short circuit 

and could cause personal injury due to electric shock. Never immerse the unit, and avoid any area where standing water might 
accumulate. Mounting should be in the driest location available.

• Leave a minimum of 2" clearance at front and back of the Inverter/Charger for proper ventilation. To avoid automatic Inverter/Charger

shutdown due to overtemperature, any compartment that contains the Inverter/Charger must be properly ventilated with adequate 
outside air flow. The heavier the load of connected equipment, the more heat will be generated by the unit.

• Do not install the Inverter/Charger directly near magnetic storage media, as this may result in data corruption.

• Do not install near flammable materials, fuel or chemicals.

Battery Connection Warnings

• The Inverter/Charger will not operate (with or without utility power) until batteries are connected.

• Multiple battery systems must be comprised of batteries of identical voltage, age, amp-hour capacity and type.

• Because explosive hydrogen gas can accumulate near batteries if they are not kept well ventilated, your batteries should not be 

installed (whether for a mobile or stationary application) in a “dead air” compartment. Ideally, any compartment would have some 
ventilation to outside air. 

• Sparks may result during final battery connection. Always observe proper polarity as batteries are connected.

• Do not allow objects to contact the two DC input terminals. Do not short or bridge these terminals together. Serious personal injury 

or property damage could result.

Equipment Connection Warnings

Do not use a Tripp Lite RV Inverter/Charger in life support or healthcare applications where a malfunction or failure of a 
Tripp Lite RV Inverter/Charger could cause failure of, or significantly alter the performance of, a life support device or
medical equipment.

• Corded models: Do not modify the Inverter/Charger’s plug or receptacle in a way that eliminates its ground connection. Do not use 

power adapters that will eliminate the plug’s ground connection.

• Connect your Inverter/Charger only to a properly grounded AC power outlet or hardwired source. Do not plug the unit into itself; this 

will damage the device and void your warranty.

• You may experience uneven performance results if you connect a surge suppressor, line conditioner or UPS system to the output of 

the Inverter/Charger.

Operation Warnings

• Your Inverter/Charger does not require routine maintenance. Do not open the device for any reason. There are no user serviceable parts 

inside.

• Potentially lethal voltages exist within the Inverter/Charger as long as the battery supply and/or AC input are connected. During any 

service work, the battery supply and AC input connection (if any) should therefore be disconnected.

• Do not connect or disconnect batteries while the Inverter/Charger is operating in either inverting or charging mode. Operating Mode 

Switch should be in the OFF position. Dangerous arcing may result.

Содержание PowerVerter RV1012UL

Страница 1: ...remium Protection Levels Built In ISOBAR Surge Protection Automatic Overload Protection Ideal Output for All Loads including computers Frequency Controlled Output Fast Load Switching Balanced Load Sharing Better for Your Batteries Faster Battery Recharge High Amp 3 Stage Battery Charger adjustable Critical Battery Protection Battery Charge Conserver Load Sense Battery Temperature Sensing High Effi...

Страница 2: ...Hardwire Hardwire Hardwire Hardwire Hardwire Hardwire Hardwire INVERTER Common Specifications for All Models DC Input Volts Nominal 12 VDC DC Input Voltage Range 10 15 VDC Output Volts Nominal 120 VAC 5 Output Frequency Nominal 60 Hz 0 5 Efficiency 88 to 94 depending on load and temperature Select Tripp Lite Inverter Chargers include a Battery Charge Conserver Load Sense Control which saves batter...

Страница 3: ... be installed whether for a mobile or stationary application in a dead air compartment Ideally any compartment would have some ventilation to outside air Sparks may result during final battery connection Always observe proper polarity as batteries are connected Do not allow objects to contact the two DC input terminals Do not short or bridge these terminals together Serious personal injury or prop...

Страница 4: ...I receptacle output See page 11 for connection instructions Resettable Circuit Breaker protect your Inverter Charger against damage due to overload See page 5 for resetting instructions Remote Control Module Connector allows remote monitoring and control with an optional module Tripp Lite model APSRM2 sold separately or included with select models See remote module owner s manual for connection in...

Страница 5: ...erator source If the operating mode switch is set to CHARGE ONLY this light will BLINK to alert you that the unit s inverter is OFF and will NOT supply AC power in the absence of a utility generator source or in over under voltage situations INV Inverting Yellow Indicator This light will ILLUMINATE CONTINUOUSLY whenever connected equipment is receiving battery supplied inverted AC power in the abs...

Страница 6: ...o momentary high low line voltage swings that would have little effect on equipment operation you may wish to adjust these settings By increasing the High AC Voltage Point and or decreasing the Low AC Voltage Point you will reduce the number of times your unit switches to battery due to voltage swings Group B DIP Switches Not on 612 Models Select Load Sharing OPTIONAL Not on 612 Models Your Invert...

Страница 7: ...t s inverter automatically shuts off in the absence of any power demand from connected equipment or appliances the electrical load When the unit detects a load it automatically turns its inverter function on Users may choose the minimum load the Inverter Charger will detect by adjusting the Battery Charge Conserver Dial see diagram Using a small tool turn the dial clockwise to lower the minimum lo...

Страница 8: ...ve by the battery voltage 12 to determine the DC amps required STEP 3 Estimate Battery Amp Hours Required for operation unsupported by the alternator Multiply the DC amps required from step 2 above by the number of hours you estimate you will operate your equipment exclusively from battery power before you have to recharge your batteries with utility or generator supplied AC power Compensate for i...

Страница 9: ...rter Charger cabinet Install and tighten two user supplied 6 mm fasteners into the mounting feet molded on the rear of the Inverter Charger cabinet The rear feet extend beyond the unit s cabinet to provide for adequate ventilation space behind the cooling fan s they should not be removed 6 4 727 32 6 11 4 cm 17 1 cm 20 cm 17 1 cm C B M A C B M A B A B C 10 26 4 cm 3 Note RV model cabinets may have...

Страница 10: ...rical system In most vehicles the Inverter Charger will be connected to one or more dedicated auxiliary house batteries which are isolated from the drive system to prevent possible draining of the main battery 12 Volt Inverter Charger 12 Volts 12 Volts 3 5 12 Volt Main Battery Connection 12 Volt Alternator Vehicle Battery Ground 12 Volt Main Battery 12 Volt Auxiliary House Battery UL Listed Fuse F...

Страница 11: ...e on each 120V leg or two different 120V sources The Inverter Charger will only supply 120V output power and WILL NOT provide 240V output even if it is connected to inputs from a split 240V service when in inverter mode When the Inverter Charger is receiving AC power it can supply connected loads with up to 20 amps of power on each circuit When the Inverter Charger is not receiving AC power and ha...

Страница 12: ...oving Operating Mode Switch to OFF Wait 1 minute Switch to AUTO REMOTE or CHARGE ONLY Battery Not Recharging Connected batteries are dead Check and replace old batteries AC Input Present Battery fuse is blown Check and replace fuse Battery cabling is loose Check and tighten or replace cabling Unit has shut down due to battery overcharge preventing Disconnect any auxiliary chargers Reset by moving ...

Отзывы: