Tripp Lite PowerVerter RV1012UL Скачать руководство пользователя страница 4

4R

Feature Identification

Identify the premium features on your specific model and quickly locate instructions on how to maximize their use.

Configuration DIP

Switches:

optimize Inverter/Charger

operation depending on your application. See pages 6-7 for 
setting instructions.

Operating Mode Switch:

controls Inverter/Charger operation. 

The “AUTO/REMOTE” setting ensures your equipment 
receives constant, uninterrupted AC power. It also enables the 
Inverter/Charger to be remotely monitored and controlled with 
an optional remote module (Tripp Lite model APSRM2, sold
separately or included with select models). The “CHARGE
ONLY” setting allows your batteries to return to full charge faster
by turning the inverter off which halts battery discharging. See
page 5 for setting instructions.

Operation Indicator Lights:

intuitive “traffic light” signals 

show whether the Inverter/Charger is operating from AC line 
power or DC battery power. It also warns you if the connected 
equipment load is too high. See page 5 for instructions on 
reading indicator lights.

Battery Indicator Lights:

intuitive “traffic light” signals show 

approximate charge level of your battery. See page 5 for 
instructions on reading indicator lights.

DC Power Terminals:

connect to your battery terminals. See 

page 10 for connection instructions.

Ground Fault Interrupter (GFI) AC Receptacles (not on 
hardwire models):

allow you to connect equipment that would

normally be plugged into a utility outlet. They feature ground 
fault interrupter switches that trip if there is excessive current 
on the ground safety wire. 

AC Input Cord (not on hardwire models):

connects the 

Inverter/Charger to any source of utility- or generator-supplied 
AC power. See page 11 for connection instructions.

Hardwire AC Input/Output Terminals (not on corded 
models):

securely connect the Inverter/Charger to vehicle or

facility electrical system input and recommended GFCI receptacle
output. See page 11 for connection instructions.

Resettable Circuit Breaker:

protect your Inverter/Charger against

damage due to overload. See page 5 for resetting instructions.

Remote Control Module Connector:

allows remote monitoring

and control with an optional module (Tripp Lite model
APSRM2, sold separately or included with select models). See
remote module owner’s manual for connection instructions.

Battery Charge Conserver (Load Sense) Dial (not on 612
models):

conserves battery power by setting the low-load level

at which the Inverter/Charger’s inverter automatically shuts off.
See page 7 for setting instructions.

Main Ground Lug:

properly grounds the Inverter/Charger to

vehicle grounding system or to earth ground. See page 
10 for connection instructions.

Multi-Speed Cooling Fan:

quiet, efficient fan prolongs equipment

service life.

DC Power Terminal Cover Plate

Hardwire AC Input/Output Cover Plate

Battery Temperature Sensing Connector (not on 612 models):

prolongs battery life by adjusting charge based on battery tem-
perature. Use with cable (included on select models). See page
7 for details.

Automatic Generator Start Connector (not on 612 models):

automatically cycles generator based on battery voltage. Use
with user-supplied cable. See page 7 for details.

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

HOT    IN

NEUTRAL    IN

GROUND    IN

GROUND    OUT

HOT    OUT

“FOR USE WITH COPPER WIRE ONLY”

NEUTRAL    OUT

1

2

4

3

5

9

10

11

13

14

8

15

Front View (Single Input/Output Hardwire Models)

12

Rear View (Single Input/Output Hardwire Models and Select Corded Models)

AC IN 1

HOT - BROWN 
NEU - BLUE
GND - GRN/YEL

AC IN 2

HOT - GRAY 
NEU - WHITE
GND - GRN/YEL

AC OUT 1

HOT - BLACK 
NEU - YELLOW
GND - GRN/YEL

AC OUT 2

HOT - ORANGE 
NEU - RED
GND - GRN/YEL

1

2

4

3

5

9

10

11

13

Front View (Dual Input/Output Hardwire Models)

Front View (Corded Models) 

* 612 models have only one set of DIP Switches. ** Select models include front-mounted ground lug. † Available on all models except 612 models.

2

4

3

5

6

7

9

10

11

13

14

1

*

12

**

8

16

17

16

17

Side Mounted, 
Not Shown

Side Mounted, 
Not Shown

16

17

Side Mounted, 
Not Shown

Side Mounted, 
Not Shown

16

17

12

Содержание PowerVerter RV1012UL

Страница 1: ...remium Protection Levels Built In ISOBAR Surge Protection Automatic Overload Protection Ideal Output for All Loads including computers Frequency Controlled Output Fast Load Switching Balanced Load Sharing Better for Your Batteries Faster Battery Recharge High Amp 3 Stage Battery Charger adjustable Critical Battery Protection Battery Charge Conserver Load Sense Battery Temperature Sensing High Effi...

Страница 2: ...Hardwire Hardwire Hardwire Hardwire Hardwire Hardwire Hardwire INVERTER Common Specifications for All Models DC Input Volts Nominal 12 VDC DC Input Voltage Range 10 15 VDC Output Volts Nominal 120 VAC 5 Output Frequency Nominal 60 Hz 0 5 Efficiency 88 to 94 depending on load and temperature Select Tripp Lite Inverter Chargers include a Battery Charge Conserver Load Sense Control which saves batter...

Страница 3: ... be installed whether for a mobile or stationary application in a dead air compartment Ideally any compartment would have some ventilation to outside air Sparks may result during final battery connection Always observe proper polarity as batteries are connected Do not allow objects to contact the two DC input terminals Do not short or bridge these terminals together Serious personal injury or prop...

Страница 4: ...I receptacle output See page 11 for connection instructions Resettable Circuit Breaker protect your Inverter Charger against damage due to overload See page 5 for resetting instructions Remote Control Module Connector allows remote monitoring and control with an optional module Tripp Lite model APSRM2 sold separately or included with select models See remote module owner s manual for connection in...

Страница 5: ...erator source If the operating mode switch is set to CHARGE ONLY this light will BLINK to alert you that the unit s inverter is OFF and will NOT supply AC power in the absence of a utility generator source or in over under voltage situations INV Inverting Yellow Indicator This light will ILLUMINATE CONTINUOUSLY whenever connected equipment is receiving battery supplied inverted AC power in the abs...

Страница 6: ...o momentary high low line voltage swings that would have little effect on equipment operation you may wish to adjust these settings By increasing the High AC Voltage Point and or decreasing the Low AC Voltage Point you will reduce the number of times your unit switches to battery due to voltage swings Group B DIP Switches Not on 612 Models Select Load Sharing OPTIONAL Not on 612 Models Your Invert...

Страница 7: ...t s inverter automatically shuts off in the absence of any power demand from connected equipment or appliances the electrical load When the unit detects a load it automatically turns its inverter function on Users may choose the minimum load the Inverter Charger will detect by adjusting the Battery Charge Conserver Dial see diagram Using a small tool turn the dial clockwise to lower the minimum lo...

Страница 8: ...ve by the battery voltage 12 to determine the DC amps required STEP 3 Estimate Battery Amp Hours Required for operation unsupported by the alternator Multiply the DC amps required from step 2 above by the number of hours you estimate you will operate your equipment exclusively from battery power before you have to recharge your batteries with utility or generator supplied AC power Compensate for i...

Страница 9: ...rter Charger cabinet Install and tighten two user supplied 6 mm fasteners into the mounting feet molded on the rear of the Inverter Charger cabinet The rear feet extend beyond the unit s cabinet to provide for adequate ventilation space behind the cooling fan s they should not be removed 6 4 727 32 6 11 4 cm 17 1 cm 20 cm 17 1 cm C B M A C B M A B A B C 10 26 4 cm 3 Note RV model cabinets may have...

Страница 10: ...rical system In most vehicles the Inverter Charger will be connected to one or more dedicated auxiliary house batteries which are isolated from the drive system to prevent possible draining of the main battery 12 Volt Inverter Charger 12 Volts 12 Volts 3 5 12 Volt Main Battery Connection 12 Volt Alternator Vehicle Battery Ground 12 Volt Main Battery 12 Volt Auxiliary House Battery UL Listed Fuse F...

Страница 11: ...e on each 120V leg or two different 120V sources The Inverter Charger will only supply 120V output power and WILL NOT provide 240V output even if it is connected to inputs from a split 240V service when in inverter mode When the Inverter Charger is receiving AC power it can supply connected loads with up to 20 amps of power on each circuit When the Inverter Charger is not receiving AC power and ha...

Страница 12: ...oving Operating Mode Switch to OFF Wait 1 minute Switch to AUTO REMOTE or CHARGE ONLY Battery Not Recharging Connected batteries are dead Check and replace old batteries AC Input Present Battery fuse is blown Check and replace fuse Battery cabling is loose Check and tighten or replace cabling Unit has shut down due to battery overcharge preventing Disconnect any auxiliary chargers Reset by moving ...

Отзывы: