128
L2SWITCH(config)# interface interface 1/0/4
L2SWITCH(config-if)# vlan-stacking tunnel-tpid index 6
L2SWITCH(config-if)# exit
L2SWITCH(config)# exit
L2SWITCH# show vlan-stacking
L2SWITCH# show vlan-stacking tpid-table
L2SWITCH# show vlan-stacking selective-qinq
Default Setting:
VLAN Stacking is disabled.
6.3.7.1
VLAN Stacking
6.3.7.1.1
CLI Configuration
Node
Command
Description
enable
show vlan-stacking
This command displays the current vlan-stacking
type.
enable
show vlan-stacking tpid-
inform
This command displays the TPID configurations.
enable
configure terminal
This command changes the node to configure
node.
configure vlan-stacking (disable|port-
based|selective)
This command disable the vlan stacking or
enable the vlan-stacking with port-based or
selective on the switch.
configure vlan-stacking tpid-table index
<2-6> value STRINGS
This command configures TPID table.
configure interface IFNAME
This command enters the interface configure
node.
interface
vlan-stacking tunnel-tpid
index <1-6>
This command sets TPID for a Q-in-Q tunnel
port.
configure interface range
gigabitethernet1/0/PORTLIS
TS
This command enters the if-range configure
node.
if-range
vlan-stacking tunnel-tpid
index <1-6>
This command sets TPID for a Q-in-Q tunnel
port.
Содержание NGI-M08C4-L2